🧩 ABB Bailey INICT03A Symphony Infi-Net to Computer Transfer Module – Product Overview
The ABB Bailey INICT03A is a high-performance Infi-Net to Computer Transfer Module designed for integration with ABB’s Symphony automation systems. This module facilitates seamless data transfer between Infi-Net network nodes and computer-based control or monitoring systems, enabling real-time data acquisition, supervisory control, and system diagnostics. The INICT03A ensures reliable communication in critical process control environments, including power generation, chemical processing, and industrial manufacturing.
⚙️ Product Features
- Model: INICT03A
- Manufacturer: ABB (Bailey Controls)
- Product Type: Data Transfer / Interface Module
- Function: Converts Infi-Net network signals for computer-based system interfaces
- System Compatibility: ABB Symphony, Infi-Net architecture
- Mounting Type: Rack-mounted module, standard 19-inch compatible
- Weight: Approx. 0.8 kg
- Dimensions: 330 mm × 210 mm × 35 mm
- Operating Temperature: 0°C to +60°C
- Storage Temperature: -40°C to +85°C
- Humidity Range: 5% to 95% non-condensing
- Connector Type: DB-25 and ribbon cable interfaces for computer connections
- Isolation Voltage: 1500 VDC between network and logic circuits
- LED Indicators: Status, communication activity, and fault detection
📊 Technical Datasheet
| Parameter | Description |
|---|---|
| Power Supply | 5 VDC ±5% |
| Current Consumption | 0.85 A typical |
| Data Transfer Rate | 19.2 kbps standard Infi-Net speed |
| Interface Type | RS-232/RS-422 serial ports |
| Network Protocols | ABB Infi-Net standard protocols |
| Signal Processing | Error checking, signal conditioning |
| Isolation | Optical isolation between network and host interface |
| Board Material | Multi-layer FR-4 PCB with conformal coating for industrial protection |
| Diagnostics | Onboard LED display for network and host communication status |
| EMI Protection | Integrated filters for high industrial noise immunity |
| Firmware Version | Standard INICT03A revision with enhanced reliability |
| Cooling Method | Passive convection cooling, optional forced-air support |
| Compliance | CE, UL, RoHS, and industrial EMC standards |
🔧 Installation & Setup
- Power Down: Ensure the host computer and Infi-Net system are completely powered off before installation.
- ESD Precautions: Handle the module with an antistatic wrist strap and avoid touching exposed circuitry.
- Mounting: Align the INICT03A module carefully into its designated rack slot. Use screws or retention clips to secure the module firmly.
- Connectivity: Attach DB-25 or ribbon connectors to the host computer interface, ensuring correct pin alignment. Connect the Infi-Net network cable to the module’s network port.
- Initial Power-On: Gradually power up the network and host system. Observe LED indicators for correct operation: green LEDs indicate proper data communication, while red indicates faults or misconfigurations.
- Configuration: Follow ABB Symphony system configuration tools to assign network addresses and verify communication integrity.
🧰 Maintenance & Handling
- Inspection: Periodically inspect connectors, cables, and LEDs for signs of wear or damage.
- Cleaning: Use a soft antistatic brush or compressed air to remove dust. Avoid liquids.
- Storage: Store the module in antistatic packaging in a dry, controlled environment.
- Replacement: Only replace with identical INICT03A modules to maintain system compatibility.
- Firmware Updates: Conduct upgrades through ABB-approved service tools to avoid communication errors.
⚠️ Usage Precautions
- Ensure the module is not exposed to high electromagnetic interference sources.
- Maintain proper airflow to prevent overheating.
- Do not connect or disconnect network cables while the system is powered.
- Verify firmware and protocol compatibility with the host computer system.
- Avoid mechanical shocks or vibration that could damage the board.
🔗 Purchase & Support
For authentic ABB Bailey INICT03A modules and compatible components, visit:
👉 https://www.fy-module.com/
👉 https://www.fy-module.com/product/
📦 Recommended Similar Products
| Model | Description | Link |
|---|---|---|
| INICT02A | ABB Infi-Net Communication Module | View Product |
| INICT04A | ABB Symphony Data Interface Board | View Product |
| INICT05A | ABB Infi-Net Remote Transfer Module | View Product |
| INICT06A | ABB Network-to-PC Interface Card | View Product |
| INICT07A | ABB Data Acquisition Interface Module | View Product |
| INICT08A | ABB High-Speed Infi-Net Transfer Module | View Product |
🧠 Summary
The ABB Bailey INICT03A module is a critical component for linking Infi-Net networks to computer-based systems. With high reliability, industrial-grade protection, and robust diagnostics, it ensures accurate and continuous data flow. Its compact design, ease of installation, and durable construction make it ideal for industrial automation environments where system integrity and communication reliability are paramount.
This module exemplifies ABB’s commitment to precision, reliability, and long-term performance in process control networks, making it an essential element in modern industrial control architectures.