DET-TRONICS 000505-027 X33AFA4M16W2 with BNB-300/32

DET-TRONICS 000505-027 X33AFA4M16W2 with BNB-300/32

The DET-TRONICS 000505-027 X33AFA4M16W2 with BNB-300/32 is a highly advanced fire and gas detection system, designed for critical applications where safety is paramount. This system is often used in industries such as oil and gas, petrochemical, and manufacturing, where rapid detection of hazardous gases or fire risks is necessary for protecting both people and property. The system offers high sensitivity, reliability, and the ability to integrate with other safety systems, ensuring maximum operational safety.

Det-Tronics Enhances its X3301 Multispectrum Infrared Flame Detector - Det- Tronics

Key Features:

  • Advanced Detection Technology: Incorporates advanced fire and gas detection technologies that offer fast response times to minimize risks.
  • Versatile Sensors: Equipped with multi-sensing capabilities, allowing the system to detect a wide range of gases and flame types.
  • Remote Monitoring: Supports remote access and monitoring, enabling continuous system health checks and diagnostics.
  • Robust Construction: Designed to withstand harsh environmental conditions, including extreme temperatures, humidity, and potential exposure to hazardous substances.
  • Highly Reliable: With a history of field-proven performance, the system provides continuous monitoring to ensure maximum safety in critical environments.
  • Easy Integration: Can be easily integrated with existing safety systems for enhanced operational control.
  • Ex-Approved: Suitable for use in hazardous locations as the system is certified for use in explosive atmospheres (ATEX, IECEx).

Technical Specifications:

  • Model: DET-TRONICS 000505-027 X33AFA4M16W2 with BNB-300/32
  • Type: Fire and Gas Detection System
  • Communication Protocols: HART, Modbus, and Profibus (for integration with control systems)
  • Voltage Input: 24V DC
  • Detection Capabilities: Includes combustible gases, toxic gases, and flame detection (UV/IR)
  • Operating Temperature Range: -40°C to +70°C (-40°F to +158°F)
  • Humidity Range: 0% to 100% RH, non-condensing
  • Certification: ATEX, IECEx, UL listed
  • Power Consumption: 5W (typical)
  • Enclosure: IP66/67 rated for outdoor installations
  • Display: LCD or LED for real-time status indication and diagnostic reporting
  • Mounting: Surface mount or panel mount options

Fire and Gas Detection Features:

  • Gas Detection: Able to detect a wide range of combustible and toxic gases such as methane, hydrogen sulfide (H2S), carbon monoxide (CO), and others.
  • Flame Detection: Uses both ultraviolet (UV) and infrared (IR) sensors for flame detection, ensuring accurate detection of various fire sources.
  • Fast Response Time: Provides rapid detection of hazards, reducing the response time and allowing for quicker mitigation actions.
  • Fault Detection: Includes self-diagnostics and fault detection to ensure system reliability, notifying operators of any issues or malfunctions.

BNB-300/32 Interface:

The BNB-300/32 is a critical part of the overall fire and gas detection system, serving as the control and communication interface that connects the various detection units to central safety systems.

  • Input/Output: Supports up to 32 detectors and multiple zones.
  • Data Logging: Records and stores historical data on alarms, faults, and system status for later analysis and reporting.
  • Communication: Fully compatible with control systems via Modbus or other communication protocols, allowing seamless integration.
  • Monitoring: Provides real-time monitoring of all connected detectors, with detailed status updates and alarm notifications.

Installation & Maintenance Instructions:

  • Installation:
    1. Mounting: Mount the X33AFA4M16W2 detectors on surfaces that offer maximum coverage, avoiding areas where physical obstructions or extreme environmental conditions might affect sensor performance.
    2. Wiring: Ensure all connections are made as per the wiring diagrams provided. For optimal operation, follow the manufacturer’s specifications for power supply, ground connections, and signal cables.
    3. Calibration: Calibrate the sensors during installation and after long-term use to maintain accurate detection.
    4. System Configuration: Configure the BNB-300/32 control unit to interface with all connected detectors, ensuring communication protocols are set up correctly for data logging and real-time monitoring.
  • Maintenance:
    1. Routine Inspections: Periodically inspect the detectors and control unit for any physical damage, corrosion, or environmental wear and tear.
    2. Sensor Testing: Perform routine testing of the gas and flame detection capabilities to ensure accuracy. This should include calibration and functionality checks according to the manufacturer’s guidelines.
    3. Software Updates: Regularly update the system’s firmware to ensure you have the latest features and fixes.
    4. Cleaning: Keep the detectors free from dust, dirt, and other environmental factors that could affect sensor performance. Clean the system following the manufacturer’s instructions.

Product Recommendations:

For advanced fire and gas detection solutions, here are similar products that can complement or replace the DET-TRONICS system:

Product Description Link
Honeywell 3000 Series Comprehensive flame and gas detection system for industrial applications. Honeywell 3000 Series
Emerson Gas Detection System Advanced gas detection for hazardous environments, suitable for offshore and onshore applications. Emerson Gas Detection
Riken Keiki GX-8000 Portable multi-gas detector for personal safety in hazardous zones. Riken Keiki GX-8000

Advantages of DET-TRONICS 000505-027 X33AFA4M16W2 with BNB-300/32:

  • Comprehensive Safety: Offers both flame and gas detection, providing a complete safety solution for industrial operations.
  • Real-time Monitoring: Facilitates instant alerts and monitoring through remote connectivity, ensuring that potential hazards are identified as soon as they occur.
  • Durable and Reliable: Built to withstand harsh industrial environments, the system operates effectively in extreme conditions.
  • Scalability: The system can be expanded to accommodate a large number of detectors and can integrate seamlessly with existing safety infrastructure.
  • Certified for Hazardous Areas: With its ATEX and IECEx certifications, the system is approved for use in hazardous environments, ensuring compliance with safety standards.

Conclusion:

The DET-TRONICS 000505-027 X33AFA4M16W2 with BNB-300/32 is a versatile, reliable, and highly effective fire and gas detection system, designed for industrial applications where safety is critical. Its advanced detection technologies, easy integration, and robust performance in hazardous environments make it a vital tool for safeguarding operations and personnel. Whether you are looking to upgrade an existing safety system or install a new one, this system offers the features and performance necessary for complete peace of mind.