Product Description
The ABB 560CMU04 (1KGT011300R0001) is a central communication unit designed for the ABB RTU560 Remote Terminal Unit platform. It integrates a 32-bit processor and multiple communication interfaces to manage data exchange between field devices, remote I/O equipment, local operator interfaces, and supervisory control systems.
The module provides two 10/100BaseT Ethernet interfaces and four configurable serial communication interfaces. Depending on the system configuration, the serial ports can support RS-232C, RS-422, or RS-485 communication.
The 560CMU04 is used in substation automation, electrical distribution, utility monitoring, and industrial SCADA applications. It serves as a central processing and communication component within a compatible RTU560 subrack.
The additional reference 1KGT011331R20 should be checked against the physical product label and equipment documentation before ordering.

Product Parameters
Brand: ABB
Model: 560CMU04
Main Part Number: 1KGT011300R0001
Additional Reference: 1KGT011331R20
Product Name: RTU560 Central Communication Unit
Product Type: Communication and Processing Module
Product Series: ABB RTU560
Processor: 32-bit Industrial CPU
Ethernet Interfaces: 2 × 10/100BaseT
Serial Interfaces: 4 configurable ports (CP1, CP2, CPA, CPB)
Serial Interface Modes: RS-232C / RS-422 / RS-485, depending on configuration
Local MMI Interface: 9-pin RS-232C Sub-D
MMI Communication Speed: 38,400 bit/s
System Backplane Interface: 48-pole DIN 41612 DIN-F connector
Time Synchronization: SNTP / IRIG-B, depending on configuration
Power Requirements: Supplied through compatible RTU560 subrack
Operating Temperature: Verify hardware revision and official documentation
Dimensions: Verify against physical unit
Net Weight: Approximately 0.21 kg
Mounting Type: RTU560 communication subrack
Country of Origin: Verify product label
Product Status: Legacy industrial automation spare part
Condition: Confirm according to the actual item supplied
Technical Specifications and Features
- Central Processing and Communication
- Integrates a 32-bit processor for RTU communication and data processing.
- Coordinates communication between the RTU system and external control equipment.
- Supports centralized handling of process events and communication tasks.
- Ethernet Communication
- Provides two 10/100BaseT Ethernet interfaces.
- Supports connection to compatible SCADA networks and industrial communication infrastructure.
- Suitable for Ethernet-based remote monitoring and data exchange.
- Configurable Serial Interfaces
- Provides four serial interfaces: CP1, CP2, CPA, and CPB.
- Supports configurable RS-232C, RS-422, or RS-485 operating modes.
- Allows communication with compatible field devices, modems, and peripheral equipment.
- Local MMI Interface
- Includes a front-panel 9-pin Sub-D RS-232C interface.
- Uses a fixed communication speed of 38,400 bit/s.
- Supports local maintenance and configuration access.
- RTU560 System Integration
- Connects to the RTU560 system bus through a 48-pole DIN-F connector.
- Designed for installation in designated communication positions within compatible subracks.
- Supports system-level data exchange and remote control applications.
- Time Synchronization
- Supports time synchronization functions through compatible SNTP or IRIG-B configurations.
- Helps maintain consistent event timestamps in substation and SCADA applications.
Industrial Applications
- Electrical substations and power distribution
- Transmission and distribution automation
- Utility SCADA systems
- Remote terminal unit installations
- Industrial communication gateways
- Water and wastewater monitoring
- Oil and gas remote monitoring
- Power plant control and supervision
- Infrastructure and energy management systems
Installation and Commissioning
- Pre-Installation Inspection
- Verify the model 560CMU04 and part number 1KGT011300R0001.
- Check the additional reference 1KGT011331R20.
- Inspect the PCB, front-panel connectors, and DIN-F backplane connector.
- Confirm that the board revision matches the existing RTU560 configuration.
- System Power Isolation
- Follow the approved RTU560 shutdown procedure.
- Isolate the relevant subrack power supply.
- Use ESD protection when handling the communication module.
- Avoid touching exposed connector contacts.
- Module Installation
- Confirm the designated communication slot in the RTU560 subrack.
- Check the guide rails and backplane connector for damage.
- Insert the module in the correct orientation.
- Secure the module according to the manufacturer’s installation instructions.
- Communication Wiring
- Connect Ethernet cables to the designated network interfaces.
- Configure serial ports according to the connected equipment requirements.
- Verify RS-232, RS-422, or RS-485 wiring and signal assignments.
- Check network addressing and communication parameters.
- Firmware and Configuration
- Confirm compatible RTU560 firmware and configuration database versions.
- Use the appropriate ABB RTU560 engineering and maintenance tools.
- Verify protocol configuration and any required software licenses.
- Back up the existing configuration before making changes.
- Commissioning and Functional Testing
- Restore power according to the approved startup procedure.
- Check module status and diagnostic indicators.
- Verify Ethernet and serial communication.
- Test data exchange with connected field devices and SCADA equipment.
- Confirm event processing and time synchronization.
- Complete communication and functional acceptance tests before returning the RTU to service.
Daily Maintenance and Care
- Inspect the RTU560 cabinet for dust, moisture, and excessive temperature.
- Check Ethernet and serial connectors for secure connections.
- Monitor module diagnostic indicators.
- Review communication alarms and network error records.
- Inspect serial cable shielding and grounding.
- Check the stability of connected communication networks.
- Maintain backups of firmware, configuration databases, and protocol settings.
- Store spare modules in antistatic packaging.
- Record hardware revisions and maintenance history.
Troubleshooting and Common Questions
Q1: What is the main function of the ABB 560CMU04?
A: It is the central communication and processing unit of the ABB RTU560 platform. It manages process events and communication with control centers and local operator systems.
Q2: How many Ethernet ports are available?
A: The module provides two 10/100BaseT Ethernet interfaces.
Q3: How many serial communication ports does it support?
A: It provides four configurable serial interfaces: CP1, CP2, CPA, and CPB.
Q4: Which serial communication standards are supported?
A: The interfaces can be configured for RS-232C, RS-422, or RS-485 operation, depending on the port and system configuration.
Q5: What is the purpose of the front-panel MMI connector?
A: It provides a local RS-232C maintenance interface. Its documented communication speed is fixed at 38,400 bit/s.
Q6: Why might the RTU560 fail to communicate with a SCADA system?
A: Possible causes include incorrect IP settings, network cable problems, serial communication parameter mismatches, protocol configuration errors, or incompatible firmware.
Q7: Does replacing the module automatically restore the original configuration?
A: Not necessarily. Firmware, configuration databases, communication settings, and applicable protocol licenses may need to be restored or verified.
Q8: Can the 560CMU04 replace other RTU560 communication modules?
A: Compatibility must be checked against the complete ordering code, subrack configuration, firmware, and interface requirements. Do not assume that all RTU560 communication units are interchangeable.
Q9: What is the relationship between 1KGT011300R0001 and 1KGT011331R20?
A: Both references are supplied in the product identification. Their exact ordering-code relationship should be confirmed from the physical labels and ABB documentation before replacement.
Safety Precautions
- Installation and commissioning must be performed by qualified automation or substation personnel.
- Isolate the relevant subrack power before inserting or removing the module.
- Follow ESD protection procedures.
- Verify backplane and connector compatibility before installation.
- Do not connect serial interfaces using unverified pin assignments.
- Confirm network configuration and protocol compatibility before commissioning.
- Follow ABB RTU560 hardware and system maintenance documentation.
Recommended ABB Related Models
- 560CMU01 – RTU560 Communication Unit
- 560CMU02 – RTU560 Communication Unit
- 560CMU03 – RTU560 Communication Unit
- 560CMR01 – 1KGT036200R0001 – RTU560 Communication Unit
- 560CSR01 – RTU560 Communication Subrack
- 560BCU02 – RTU560 Bus Connection Unit
- 560BCU03 – RTU560 Bus Connection Unit
- 560PSU01 – RTU560 Power Supply Module
- 560NET01 – RTU560 Network Communication Module
- 560DIO – RTU560 Digital I/O Module Family
- 560AIO – RTU560 Analog I/O Module Family
- 23TP21 – RTU560 Extension Subrack
- 23ET23 – RTU560 Extension Subrack
- 560ACN01 – RTU560 Automation Communication Node
- 560CMU04 – 1KGT011300R0001 – Central Communication Unit
Note: These are related RTU560 system components and communication modules. They are not all direct replacements for the 560CMU04. Verify the exact hardware reference, firmware, communication interfaces, and subrack compatibility before substitution.