Product Description
The ABB Bailey IMFBS01 Field Bus Slave Module is an intelligent interface module designed for the Bailey INFI 90 and Network 90 distributed control systems. It connects field instruments and Bailey-Fischer & Porter smart transmitters to a Multi-Function Processor (MFP) or Multi-Function Controller (MFC).
The module supports up to 15 analog or frequency shift keyed (FSK) digital signal channels. It performs analog-to-digital conversion and enables communication with compatible smart transmitters for measurement monitoring, configuration, and calibration.
The IMFBS01 supports three operating modes: FSK field bus mode, FSK analog point-to-point mode, and baseband analog point-to-point mode. It is suitable for process instrumentation, control-system maintenance, and replacement of compatible INFI 90 field interface modules.
Product Parameters
- Brand: ABB Bailey
- Model: IMFBS01
- Product Name: Field Bus Slave Module
- Product Series: INFI 90 / Network 90
- Module Type: Intelligent Field Bus Interface
- Input Channels: 15
- Signal Types: Analog and FSK digital signals
- Supported Analog Inputs: 4–20 mA, 0–1 VDC, 1–5 VDC, 0–5 VDC, 0–10 VDC, ±10 VDC
- Operating Modes: FSK field bus, FSK analog point-to-point, baseband analog point-to-point
- Processing Function: Analog-to-digital conversion and smart-transmitter communication
- Processor: Onboard microprocessor
- Memory: Onboard memory
- Installation: One slot in an INFI 90 module mounting unit (MMU)
- System Interface: I/O Expander Bus
- Power Requirements: +5 VDC ±5% at 85 mA typical; +15 VDC ±5% at 25 mA typical; -15 VDC ±5% at 20 mA typical
- Power Dissipation: 1.1 W typical
- Operating Temperature: 0°C to 70°C, non-condensing
- Dimensions: Confirm from the module and installation documentation
- Weight: Approx. 0.3 kg net reported by one supplier; confirm actual unit weight
- Country of Origin: Confirm from product label
- Product Status: Obsolete
- Product Condition: Confirm the condition of the supplied unit
Main Features
- Supports 15 analog or FSK digital input channels.
- Interfaces Bailey smart transmitters with INFI 90 control processors.
- Performs onboard analog-to-digital conversion.
- Supports field bus and point-to-point communication configurations.
- Provides transmitter communication for configuration and calibration tasks.
- Uses a dedicated module processor and communication circuitry.
- Installs in a single slot of a compatible module mounting unit.
Typical Applications
- Bailey INFI 90 distributed control systems
- Network 90 process automation systems
- Smart transmitter communication
- Industrial process measurement
- Analog field signal acquisition
- Power generation and utility control
- Chemical, petrochemical, and manufacturing plants
- Legacy DCS maintenance and spare-parts replacement
Installation and Commissioning
- Confirm the module label reads IMFBS01 and check its hardware revision.
- Verify the host system, MFP/MFC processor, MMU, and termination-unit configuration.
- Check that the required termination unit or termination module is installed. The IMFBS01 uses a field wiring connection through a compatible TU or TM.
- Isolate the relevant system power and follow the plant’s electrical safety procedures.
- Inspect the card-edge connectors, faceplate latches, and PCB for damage or contamination.
- Set the module’s I/O Expander Bus address using the onboard DIP switch according to the system configuration.
- Verify the operating mode and jumper settings against the application documentation.
- Connect field wiring according to the termination-unit diagram and the selected transmitter configuration.
- Install the module into the correct MMU slot and secure both captive faceplate latches.
- Restore power and check module status and system diagnostics.
- Verify channel readings and transmitter communication.
- Test the configured measurement range and confirm that the MFP/MFC receives the expected process data.
Daily Maintenance and Care
- Inspect faceplate latches and card-edge connectors for wear or damage.
- Check module status and communication diagnostics during routine system inspections.
- Monitor analog input values for unexpected drift or signal loss.
- Inspect field wiring, shields, grounding, and termination connections.
- Check smart-transmitter communication and configuration when abnormal readings occur.
- Keep the control cabinet clean, dry, and within the specified temperature range.
- Record module revisions, bus addresses, jumper settings, and replacement history.
- Maintain a verified backup of the relevant INFI 90 configuration.
Troubleshooting and Common Questions
Q1: What is the primary function of the IMFBS01?
A: It interfaces up to 15 analog or FSK digital field signals with an INFI 90 MFP or MFC control processor.
Q2: Which signal types does it support?
A: Documented analog input types include 4–20 mA, 0–1 VDC, 1–5 VDC, 0–5 VDC, 0–10 VDC, and ±10 VDC. It also supports compatible FSK smart-transmitter communication.
Q3: Why is a channel reading incorrect?
A: Check the transmitter output, selected operating mode, jumper configuration, field wiring, termination connections, and configured input range.
Q4: Why is the smart transmitter not communicating?
A: Check the FSK wiring, field bus or point-to-point configuration, transmitter compatibility, module jumper settings, and system diagnostics.
Q5: What should be checked if the module is not recognized?
A: Verify the MMU slot, I/O Expander Bus address, card-edge connections, power supply rails, and processor configuration.
Q6: Can the IMFBS01 replace an ordinary analog input module?
A: Not automatically. The IMFBS01 provides both analog input and smart-transmitter communication functions. Confirm the system design and termination arrangement before selecting a replacement.
Q7: Is the IMFBS01 suitable for new INFI 90 installations?
A: It is an obsolete legacy module. It is primarily relevant to existing INFI 90 and Network 90 installations requiring maintenance or spare parts.
Safety Precautions
- Installation and maintenance must be performed by qualified control-system personnel.
- Follow approved isolation and lockout procedures.
- Verify power supply polarity and voltage before installation.
- Do not change jumpers or DIP switch settings without checking the approved system configuration.
- Use ESD protection when handling the circuit board.
- Confirm termination-unit wiring and transmitter compatibility before commissioning.
Recommended ABB Bailey Related Models
The following modules are related to the Bailey INFI 90 and Network 90 control platform. They serve different functions and are not direct replacements for IMFBS01.
- ABB Bailey IMFEC11 – Field Equipment Communication Module
- ABB Bailey IMFEC12 – Analog Input Module
- ABB Bailey IMFAI01 – Isolated Analog Input Module
- ABB Bailey IMFCS01 – Frequency Counter Slave Module
- ABB Bailey IMDSI13 – Digital Input Slave Module
- ABB Bailey IMDSI22 – Digital Input Module
- ABB Bailey IMDSO01 – Digital Slave Output Module
- ABB Bailey IMDSO02 – Digital Output Module
- ABB Bailey IMDSO04 – Digital Output Slave Module
- ABB Bailey IMDSO14 – Digital Output Slave Module
- ABB Bailey IMRIO02 – Remote I/O Slave Module
- ABB Bailey IMMFP11 – Multi-Function Processor
- ABB Bailey IMMFP12 – Multi-Function Processor
- ABB Bailey IMMFC04 – Multi-Function Controller
- ABB Bailey NTFB01 – Field Bus Module Termination Unit