Product Description
The ABB RED670 is a high-performance line differential protection relay from the Relion 670 series. It is designed to protect overhead transmission lines and underground cables by comparing current measurements from different ends of a protected line and identifying internal faults.
The RED670 supports protection, control, monitoring, and communication functions for power transmission systems. Depending on its hardware configuration, software version, and ordered options, it can also provide distance protection, backup overcurrent protection, fault recording, and power system monitoring.
The 1MRK004810-AA ordering reference should be checked against the complete product identification label and configuration information before installation or replacement.

Product Parameters
Brand: ABB
Product Series: Relion 670
Model: RED670
Ordering Number: 1MRK004810-AA
Product Name: Line Differential Protection Relay
Product Type: Numerical Protection IED
Main Function: Transmission Line Differential Protection
Application: Overhead Lines and Power Cables
Protection Functions: Configuration Dependent
Communication: Configuration Dependent
Power Requirements: Verify the rated supply on the nameplate
Installation: Protection and Control Panel
Product Status: Legacy Product; Verify Availability
Condition: Used (Confirm actual item condition before listing)
Country of Origin: Not confirmed
Dimensions: Verify against the installed hardware configuration
Weight: Not confirmed
Technical Specifications and Features
- Line Differential Protection: Compares current measurements from multiple line terminals to detect internal faults.
- Fault Detection: Supports fast identification of phase and other configured line faults.
- Backup Protection: Additional protection functions may include distance and overcurrent protection, depending on the ordered configuration.
- Disturbance Recording: Supports fault and event records for post-fault analysis.
- Monitoring Functions: Provides measured values, alarms, and equipment status information.
- Communication: Supports station communication and remote-end communication options according to the installed hardware and software.
- Modular Hardware: The IED configuration may include different analog input, binary input/output, and communication modules.
- System Integration: Designed for integration into substation protection, control, and monitoring systems.
Industrial Applications
- High-voltage transmission line protection
- Underground power cable protection
- Electrical substations
- Power generation and transmission networks
- Utility protection and control systems
- Industrial power distribution networks
Installation and Commissioning
- Confirm the complete ordering code, product version, serial number, and hardware configuration.
- Verify that the relay’s auxiliary supply matches the panel supply.
- Check current transformer ratios, polarity, phase sequence, and terminal assignments.
- Verify communication links between the local and remote line terminals.
- Confirm the protection settings, differential characteristics, and communication supervision parameters.
- Use the appropriate ABB PCM600 engineering environment and compatible connectivity packages for configuration and maintenance.
- Perform secondary injection tests and communication checks before enabling trip outputs.
- Verify trip circuit wiring, interlocking, alarms, and circuit breaker operation under an approved commissioning procedure.
Commissioning should be performed by qualified protection engineers. Do not connect the relay directly to an energized protection circuit without completing the required safety and testing procedures.
Daily Maintenance and Care
- Check the front-panel LEDs and alarm indications.
- Review active alarms and event records.
- Monitor communication status with remote line terminals.
- Inspect terminal connections and panel ventilation.
- Check auxiliary supply stability.
- Back up relay settings and configuration files.
- Review disturbance records after protection operations.
- Keep the relay clean and protected from moisture, dust, and excessive temperature.
Troubleshooting and Common Questions
Q1: What is the primary function of the ABB RED670?
A: It provides differential protection for transmission lines and power cables by comparing current measurements from different ends of the protected circuit.
Q2: Can the RED670 be used for cable protection?
A: Yes. The RED670 is designed for both overhead transmission lines and underground power cables, subject to the selected application configuration.
Q3: Does every RED670 include distance protection?
A: No. Additional protection functions depend on the ordered configuration and installed software options.
Q4: Can this relay replace another RED670 unit?
A: Replacement compatibility must be confirmed by comparing the complete ordering code, hardware modules, product version, firmware, application configuration, and auxiliary supply.
Q5: What should be checked before purchasing a used unit?
A: Check the nameplate, serial number, terminal condition, front-panel condition, hardware configuration, and available test records. Confirm that the unit matches the requirements of the existing protection system.
Q6: What software is used for configuration?
A: ABB PCM600 is used for engineering and configuration of compatible Relion 670 devices. The required version and connectivity package must match the relay’s product version.
Safety Precautions
- Installation and testing must be carried out by qualified electrical protection personnel.
- Isolate and verify all relevant circuits before handling wiring.
- Never disconnect current transformer secondary circuits while primary current is flowing.
- Confirm CT polarity and circuit wiring before enabling differential protection.
- Verify protection settings and trip logic before returning the relay to service.
- Follow the plant’s approved protection testing and switching procedures.
Recommended ABB Related Models
- ABB REL670 – Line Differential Protection Relay
- ABB RED670 2.0 – Line Differential Protection IED
- ABB RED670 2.2 – Line Differential Protection IED
- ABB REL650 – Line Distance Protection IED
- ABB REL670 – Transmission Line Protection IED
- ABB RET670 – Transformer Protection and Control IED
- ABB REB670 – Busbar Protection IED
- ABB REC670 – Bay Control IED
- ABB REQ650 – Shunt Capacitor Bank Protection IED
- ABB REF615 – Feeder Protection and Control Relay
- ABB REF620 – Feeder Protection and Control Relay
- ABB RED615 – Line Differential Protection Relay
- ABB RED650 – Line Differential Protection IED
- ABB REG670 – Generator Protection IED
- ABB RELion 670 Series – Protection and Control IED Family