Product Description
The ABB REG670 is a high-performance generator protection and control Intelligent Electronic Device (IED) belonging to the Relion 670 series. It is designed to protect, control, monitor, and supervise generators and generator-transformer units in power generation facilities.
The REG670 provides an extensive range of generator protection functions, including generator differential protection, stator earth-fault protection, rotor earth-fault protection, overcurrent protection, loss-of-excitation protection, reverse-power protection, and frequency protection. Depending on the selected configuration, it can also support transformer protection, breaker failure protection, synchronizing, and other power-system functions.
The modular hardware architecture allows different power supply, analog input, binary input/output, processing, communication, and interface modules to be installed according to the application requirements.
This listing identifies an electronic module associated with the ABB REG670 platform. The exact module type, part number, hardware revision, and installed configuration should be confirmed from the physical label before ordering. The REG670 designation alone does not identify a specific replaceable electronic card.

Main Functions and Applications
- Generator electrical protection and supervision.
- Generator differential protection for internal phase faults.
- Stator earth-fault protection, including application-dependent 100% stator winding protection.
- Rotor earth-fault protection in supported configurations.
- Overcurrent, voltage, frequency, and thermal protection.
- Loss-of-excitation and pole-slip protection.
- Reverse-power and directional power protection.
- Generator-transformer unit protection.
- Breaker failure protection and synchronizing functions.
- Event recording, disturbance recording, and fault analysis.
- Communication with station automation and control systems.
Product Parameters
- Brand: ABB
- Product Family: Relion 670 Series
- Model: REG670
- Product Name: Generator Protection and Control IED
- Product Type: Modular Electronic Protection Relay
- Main Application: Generator and generator-transformer protection
- Protection Functions: Configuration-dependent
- Hardware Architecture: Modular IED
- Communication: Configuration-dependent, including supported IEC 61850 interfaces
- Auxiliary Power Supply: Depends on installed power supply module
- Analog Inputs: Depends on transformer input module configuration
- Binary Inputs/Outputs: Depends on installed I/O modules
- Electronic Module Part Number: Not provided
- Hardware Revision: Not confirmed
- Firmware Version: Not confirmed
- Place of Manufacture: Not confirmed
- Product Condition: Not specified; verify actual item condition
- Dimensions: Depend on the complete IED case configuration
- Weight: Not confirmed
- Country of Origin: Not confirmed
- Power Requirements: Depend on the installed power supply module
- Discontinued Status: Verify current availability and lifecycle status with ABB
Installation and Commissioning
- Identify the exact electronic module part number and revision from the physical label.
- Confirm that the module is intended for the specific REG670 hardware and product version.
- Isolate the relay auxiliary power and follow the station safety procedures.
- Before removing a module, record its slot position, terminal connections, and configuration.
- Inspect the module, connectors, and backplane contacts for physical damage or contamination.
- Install the replacement module in the designated slot according to ABB instructions.
- Restore auxiliary power and check the relay’s self-supervision and diagnostic indications.
- Use ABB PCM600 engineering tools, where applicable, to verify the IED configuration and communication status.
- Check analog measurements, binary inputs, output circuits, and communication interfaces relevant to the installed module.
- Perform the required protection function tests and confirm that the relay operates according to the approved protection settings.
Important: A replacement electronic module may require configuration, parameter verification, or commissioning tests. Do not assume that a physically matching card is automatically compatible with every REG670 version.
Daily Maintenance and Care
- Check the REG670 self-supervision status and active alarms.
- Review event and disturbance records for abnormal protection activity.
- Inspect the relay enclosure and module connections during scheduled maintenance.
- Monitor auxiliary supply voltage and internal diagnostic messages.
- Verify communication with the station control system.
- Check the condition of current-transformer and voltage-transformer secondary circuits.
- Review protection setting changes and maintain configuration backups.
- Perform periodic functional tests according to the plant maintenance schedule.
- Keep spare modules in antistatic packaging and record their part numbers and revisions.
Troubleshooting and Common Problems
- Module identification or hardware fault
- Check the module part number and hardware revision.
- Verify the assigned slot and connector seating.
- Review the REG670 self-supervision diagnostics.
- Analog measurement abnormality
- Inspect CT and VT secondary wiring.
- Verify transformer input module configuration.
- Check measurement scaling and protection settings.
- Binary input or output malfunction
- Inspect field wiring and terminal connections.
- Verify the installed BIM or BOM module type.
- Check the configured signal mapping and output logic.
- Communication failure
- Check Ethernet or serial connections according to the installed interface.
- Verify communication settings and network configuration.
- Review IEC 61850 communication and station-bus diagnostics where applicable.
- Protection function operates unexpectedly
- Review disturbance records and event logs.
- Verify CT/VT measurements and protection settings.
- Check logic configuration and signal assignments.
- Have qualified protection engineers investigate before returning the generator to service.
- Relay fails to start normally
- Check auxiliary supply voltage.
- Inspect the power supply module and internal diagnostics.
- Verify module installation and hardware compatibility.
Safety Precautions
- Generator protection equipment must be handled by qualified protection and control engineers.
- Isolate auxiliary power before removing or installing electronic modules.
- Never disconnect energized CT secondary circuits; use approved shorting and isolation procedures.
- Follow approved procedures for VT secondary circuits and trip-circuit isolation.
- Do not change protection settings without authorization.
- Perform secondary injection and functional testing before placing the relay back into service.
- Confirm the complete module part number and hardware revision before replacement.
- Maintain the approved protection coordination and trip logic throughout maintenance.
Recommended Related ABB Models
The following ABB Relion protection IEDs and associated equipment are relevant to generator, transformer, and power-system protection. They are related product references, not direct replacements for REG670 electronic modules.
- REG650 – Generator Protection and Control IED
- REG630 – Generator Protection and Control IED
- RET670 – Transformer Protection and Control IED
- RET650 – Transformer Protection and Control IED
- RED670 – Line Differential Protection IED
- REL670 – Line Distance Protection IED
- REL650 – Line Distance Protection IED
- REB670 – Busbar Protection IED
- REB650 – Busbar Protection IED
- REC670 – Bay Control IED
- REC650 – Bay Control IED
- REQ650 – Shunt Capacitor Bank Protection IED
- REF615 – Feeder Protection and Control Relay
- REF620 – Feeder Protection and Control Relay
- RET615 – Transformer Protection and Control Relay