The Allen-Bradley 100S-E116 is a high-performance safety contactor from the Series A range, specifically designed for mission-critical industrial safety applications. The 100S-E116KN12C model integrates advanced switching technology with mechanically linked contacts to ensure the highest levels of safety and reliability in motor control circuits. This IEC-certified device is built to monitor its own status, providing essential feedback to safety controllers in automated manufacturing environments.

Technical Specifications
| Parameter | Specification |
| Model | 100S-E116 Series A (100S-E116KN12C) |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Safety Type | Safety Contactor (IEC compliant) |
| Rated Operational Current | 116 A (AC-3) |
| Auxiliary Contacts | 1 N.O. / 2 N.C. (mechanically linked) |
| Dimensions | Approx. 185mm x 90mm x 150mm |
| Weight | Approx. 2.5 kg |
| Country of Origin | Czech Republic / USA |
Operating Procedures
Pre-Installation Check:
Verify that the rated control voltage and operational current of the contactor match your system requirements. Ensure the environment is free of excessive dust, moisture, and extreme temperatures. Confirm that all mounting hardware is securely fastened to a DIN rail or panel according to the manufacturer’s installation guide.
Power-On Sequence:
-
Ensure all safety circuits and emergency stop loops are in a closed/ready state.
-
Verify that the load side is clear of any short circuits.
-
Apply the control circuit voltage to energize the contactor coil.
-
Observe the contactor mechanical indicator to confirm that the main contacts have closed properly.
-
Once the coil is energized, the system is ready to carry the operational current to the motor or load.
Power-Off Sequence:
-
Interrupt the signal to the control circuit to de-energize the coil.
-
Verify that the contactor has transitioned to the open state (the mechanical linkage ensures forced separation of the main contacts).
-
If maintenance is required, isolate the main power source before performing any physical tasks on the wiring.
Frequently Asked Questions (Q&A)
What defines this unit as a “Safety Contactor”?
A safety contactor, such as the 100S-E116, features mechanically linked contacts. This ensures that the auxiliary contacts and main contacts cannot be closed simultaneously. If a main contact welds, the auxiliary contacts cannot change state, which is a critical diagnostic feature for safety monitoring systems.
Can I replace the coil in this unit?
Yes, the 100S-E series is designed for modular maintenance. If the coil fails, it can typically be replaced without needing to replace the entire contactor assembly, provided you use the correct genuine Allen-Bradley replacement part for the 100S-E116 frame size.
What is the purpose of the “KN12C” suffix?
The suffix indicates specific coil voltage and terminal configurations tailored for the 100S-E series. It is essential to match this exact code when ordering replacements to ensure electrical compatibility with your existing control board and signal logic.