The Alstom General Electric MVTTM14 is a static digital time-delay relay designed for delayed-on-pickup operation. Relay selection documentation identifies the MVTTM14 as a static digital time-delay relay, while the broader VTT14 documentation describes it as a static definite-time relay with delay on pickup.

| Parameter | Specification |
|---|---|
| 🏭 Brand | Alstom General Electric |
| 🔢 Model | MVTTM14C1BA1002A |
| 📚 Series | MVTTM14 / MiDOS Relay |
| ⚙️ Product Name | Static Digital Time Delay Relay |
| ⏱️ Function | Delayed On Pickup |
| 🔌 Relay Type | Static / Digital Time Delay Relay |
| 📐 Case Size | Size 3 |
| 🌎 Country of Origin | United Kingdom |
| 📦 Product Status | Legacy / Obsolete Series |
| ⚡ Power / Voltage | Exact coil/input rating depends on the complete suffix configuration |
The available relay documentation identifies MVTTM14 as the delayed-on-pickup version and MVTTM15 as the delayed-on-drop-off version. The documented standard timing ranges include 0.05, 0.1, 0.5, 1.0 and 2.5 seconds, with higher ranges of 0.5, 1, 5, 10 and 25 seconds also listed for the VTT family.
⚙️ Product Features
⏱️ Time-Delay Function — MVTTM14 is designed for delay-on-pickup, meaning the output operates after the preset time delay following energization.
🔧 Static Digital Design — The MVTTM14 is classified as a static digital time-delay relay rather than a conventional electromechanical timing relay.
🏭 Industrial Protection & Control — The relay belongs to the Alstom/GE relay family used in electrical protection and control applications.
🔌 MiDOS Casing — MVTTM14 is listed among relays installed in the MiDOS casing family.
🔄 Multiple Timing Ranges — VTT-family documentation lists several standard timing ranges, from fractions of a second through 25 seconds.
📦 Specific Suffix Matters — The complete ordering code MVTTM14C1BA1002A should be checked before substitution because electrical characteristics and contact arrangements can depend on the detailed configuration.
📐 Dimensions & Weight
📏 Case Size: Size 3 is identified for the MVTTM14 in the available relay documentation.
⚖️ Weight: A reliable manufacturer weight specification for the exact MVTTM14C1BA1002A was not located, so a numerical weight should not be assumed.
📐 Exact Dimensions: The available sources identify the case size but do not provide sufficiently reliable dimensions for this exact suffix.
❓ Frequently Asked Questions
Q: What is the Alstom MVTTM14?
A: It is a static digital time-delay relay designed for delayed-on-pickup operation.
Q: What does “delay on pickup” mean?
A: After the relay receives its operating signal, the output does not change immediately. It operates after the preset time delay has elapsed.
Q: What is the difference between MVTTM14 and MVTTM15?
A: MVTTM14 provides delay on pickup, while MVTTM15 provides delay on drop-off.
Q: What timing ranges are available?
A: Documentation for the VTT family lists standard ranges including 0.05, 0.1, 0.5, 1.0 and 2.5 seconds, as well as 0.5, 1, 5, 10 and 25 seconds. The exact range for the suffix C1BA1002A should be verified from its nameplate or original ordering documentation.
Q: Is MVTTM14 an electromechanical relay?
A: No. It is classified as a static digital time-delay relay.
Q: What is the case size?
A: The available documentation lists MVTTM14 as Size 3 in the MiDOS relay casing family.
Q: Is MVTTM14 still a current product?
A: It appears to be a legacy Alstom/GE relay family rather than a current-generation product. Current availability is therefore generally associated with replacement stock, surplus inventory, or refurbished equipment.
Q: Can another MVTTM14 replace MVTTM14C1BA1002A?
A: Not automatically. The complete ordering code should be matched because input voltage, timing configuration, contacts and other options may differ.
Q: What should I check before purchasing?
A: Check the complete MVTTM14C1BA1002A code, nameplate voltage, timing range, contact configuration, case arrangement, terminal layout and physical condition.
🔢 15 Related Alstom / GE Models
- Alstom MVTTM15 — Static Digital Time Delay Relay, Delay on Drop-Off
- Alstom VTT14 — Static Definite Time Relay, Delay on Pickup
- Alstom VTT15 — Static Definite Time Relay, Delay on Drop-Off
- Alstom VTT12 — Static Time Delay Relay
- Alstom VTUM21 — Static Definite Time Under/Over Voltage Relay
- Alstom VTU31 — Static Combined Definite-Time & Instantaneous Overvoltage Relay
- Alstom VTX31 — CT Bus-Wire Protection Pilot Supervision Relay
- Alstom MVAPM32 — Voltage Selection Relay
- Alstom MVAAM11 — Voltage Operated Auxiliary Relay
- Alstom MVAAM21 — Two-Element Auxiliary Relay
- Alstom MVAAM31 — Three-Element Auxiliary Relay
- Alstom MVAJM11 — Voltage Operated Tripping Relay
- Alstom MVAJM13 — Voltage Operated Tripping Relay
- Alstom MVAXM21 — Trip Circuit Supervision Relay
- Alstom MVAJ204-L — Electrically Reset Tripping Relay
The MVTTM14/MVTTM15, VTT14/VTT15 and related relay functions are documented in Alstom/GE relay-selection material.