ALSTOM | RTx-152 | Timing and Measuring Relay

Product Description

The ALSTOM RTx-152 is identified as a timing and measuring relay designed for use in industrial electrical control and protection systems. Timing and measuring relays are commonly used to monitor electrical conditions, provide time-dependent control functions, and coordinate switching or alarm sequences.

The RTx-152 may be used as a replacement component in legacy control panels and electrical installations where the original relay type is specified. Before installation, confirm the complete model designation, terminal arrangement, auxiliary supply, measuring inputs, and operating settings against the equipment documentation.

ABB PM573-ETH A9 1SAP130300R0271 Central Processing Unit DC541 Digital IO Module Image 1 of 4

Product Parameters

  • Brand: ALSTOM
  • Model: RTx-152
  • Product Name: Timing and Measuring Relay
  • Product Category: Industrial Control and Protection Relay
  • Series: RTx Series
  • Application: Electrical monitoring, timing, and control circuits
  • Place of Manufacture: Not confirmed
  • Product Status: Not specified
  • Dimensions: Not verified; check the product label and physical unit
  • Weight: Not verified
  • Country of Origin: Not confirmed
  • Power Requirements: Auxiliary supply rating not verified
  • Measuring Range: Not verified
  • Timing Range: Not verified
  • Mounting Type: Confirm from the unit and installation documentation
  • Discontinued Status: Current production status not confirmed

Installation and Commissioning

  1. Verify that the relay model and complete part number match the equipment bill of materials.
  2. Isolate the control panel and confirm that all relevant circuits are de-energized.
  3. Check the relay housing, terminals, connectors, and mounting points for damage or corrosion.
  4. Compare the wiring diagram with the relay terminal markings before connecting auxiliary power or measuring inputs.
  5. Confirm the required supply voltage, input signal range, timing settings, and output contact ratings from the manufacturer documentation.
  6. Apply power only after wiring and configuration checks are complete.
  7. Test the relay’s measuring response, timing operation, output contacts, and alarm or interlock interface under controlled conditions.

Daily Maintenance and Care

  • Check the relay enclosure and terminals for dust, moisture, corrosion, or loose connections.
  • Review panel alarms and operating records for unexpected relay activation.
  • Confirm that connected measuring circuits remain correctly wired and shielded where required.
  • Keep the surrounding panel within the environmental limits specified for the equipment.
  • Record inspection results and any changes to relay settings.
  • Do not adjust timing or measuring parameters without an approved control-system procedure.

Troubleshooting and Common Problems

  • No relay operation: Check auxiliary power, protective fuses, wiring, and the configured operating conditions.
  • Incorrect timing response: Verify the timing settings and compare the actual sequence with the approved control logic.
  • Unstable measuring behavior: Inspect the measuring input wiring, signal quality, grounding, and connected sensors or transducers.
  • Output contact failure: Check the external circuit, contact loading, terminal condition, and relay output operation.
  • Intermittent operation: Inspect for loose terminals, vibration, moisture, overheating, or unstable supply voltage.

Safety Precautions

  • Installation and testing should be performed by qualified electrical personnel.
  • Isolate power and follow the site’s lockout/tagout procedure before handling wiring.
  • Never assume the auxiliary supply or measuring-input rating from the model name alone.
  • Do not exceed the verified contact, voltage, or current ratings.
  • Test protection and interlock circuits before returning the equipment to service.
  • Use the manufacturer’s wiring and commissioning documentation for final configuration.

Recommended ALSTOM Models

The following are related ALSTOM protection and control relay families that may be relevant when maintaining legacy electrical systems. They are not confirmed direct substitutes for the RTx-152.

  • MCGG – Numerical and electromechanical protection relay family
  • MiCOM P120 – Overcurrent protection relay
  • MiCOM P121 – Overcurrent protection relay
  • MiCOM P122 – Overcurrent protection relay
  • MiCOM P123 – Overcurrent protection relay
  • MiCOM P127 – Overcurrent protection relay
  • MiCOM P141 – Feeder management relay
  • MiCOM P142 – Feeder management relay
  • MiCOM P143 – Feeder management relay
  • MiCOM P225 – Motor protection relay
  • MiCOM P225T – Motor protection relay variant
  • MiCOM P343 – Generator protection relay
  • MiCOM P441 – Distance protection relay
  • MiCOM P442 – Distance protection relay
  • MiCOM P443 – Distance protection relay
Share this story: