Automated Logic SE6104SP BACnet Advanced Control Module

Automated Logic SE6104SP BACnet Advanced Control Module – HVAC BMS Controller

Product Overview

The Automated Logic SE6104SP is an advanced BACnet-compatible control module specifically designed for building management systems (BMS) and HVAC applications. This controller provides precise monitoring, control, and optimization of HVAC equipment, ensuring energy efficiency, occupant comfort, and reliable system performance.

Equipped with multiple I/O points and BACnet MS/TP or IP communication capabilities, the SE6104SP enables integration with complex building automation networks. Its modular design supports scalable deployment across commercial buildings, industrial facilities, and institutional campuses. The controller’s intuitive configuration tools allow for seamless programming, diagnostics, and system visualization.

Key Features:

  • HVAC Control: Supports temperature, humidity, and airflow regulation for multiple zones.
  • 🌐 BACnet Communication: MS/TP and optional IP connectivity for full interoperability with BACnet-compliant devices.
  • 📊 Real-Time Monitoring: Tracks analog and digital inputs, outputs, and operational status of connected devices.
  • 🛡️ Alarming & Event Logging: Configurable alarms, historical event storage, and trend tracking.
  • 🔌 Flexible I/O: Multiple analog and digital inputs/outputs for sensors, actuators, and relays.
  • 🖥️ User Interface: Accessible via BMS software for configuration, monitoring, and firmware updates.

Technical Specifications

Parameter Specification
Model Automated Logic SE6104SP
Controller Type BACnet Advanced Control Module
Communication Protocols BACnet MS/TP, BACnet/IP optional
Digital Inputs 16 universal inputs (dry contact or voltage)
Analog Inputs 8 analog inputs, 0–10 VDC or 4–20 mA
Digital Outputs 8 relay outputs, 24 VAC/DC
Analog Outputs 4 analog outputs, 0–10 VDC
Operating Voltage 24 VAC ±10%, 50/60 Hz
Operating Temperature 0°C to 50°C
Relative Humidity 5%–95% non-condensing
Mounting DIN rail or panel mount
Event Logging Up to 1000 events stored internally
Power Consumption <15 W typical
Enclosure Rating IP20

Installation & Maintenance Guidelines

Installation Tips:

  1. Mount the controller on a stable surface or DIN rail away from heat sources.
  2. Ensure proper separation from high-voltage equipment to prevent interference.
  3. Connect all input/output devices according to the wiring diagram in the manual.
  4. Verify BACnet network termination and addressing for proper communication.

Maintenance Recommendations:

  • Inspect terminal connections periodically to ensure they are secure.
  • Clean the module with a dry cloth; avoid chemical cleaners.
  • Monitor firmware updates through the BMS software to maintain system performance.
  • Perform functional testing of inputs, outputs, and alarms after installation or system modifications.

Safety Precautions:

  • ⚠️ Disconnect power before servicing the controller.
  • ⚠️ Do not exceed rated voltage, current, or environmental limits.
  • ⚠️ Only trained personnel should perform installation, wiring, or firmware updates.

Recommended Similar Products

Product Model Description Link
Automated Logic SE6102SP Compact BACnet module for single-zone control View
Automated Logic SE6110 Multi-zone HVAC controller with advanced scheduling View
Automated Logic SE6120 High-capacity BACnet controller for large buildings View
Automated Logic SE6200 BACnet/IP advanced control module with extended I/O View
Automated Logic SE6150 Integrated temperature, humidity, and energy monitoring controller View

Purchase & Support:
For detailed specifications or to order the SE6104SP BACnet Advanced Control Module, visit:

Share this story: