Product Description
The GE Fanuc IC695CMU310-BC is a Max-ON Hot-Standby Redundancy CPU designed for the PACSystems RX3i programmable automation controller platform. It uses a 300 MHz processor and provides 10 MB of user memory for industrial control applications requiring high availability and standby controller capability.
The Max-ON architecture uses two separate RX3i systems that exchange operating data through dedicated Ethernet communication links. One controller operates as the active system while the other remains on standby. If the active controller encounters a fault, the standby system can take over control.
The IC695CMU310-BC supports two built-in serial communication ports: one RS-232 and one RS-485. It is designed for use with an RX3i Universal Backplane, compatible power supplies, Ethernet modules, and Max-ON application software.
This CPU is suitable for legacy control installations where controller redundancy and continuity of operation are important.

Product Parameters
- Brand: GE Fanuc
- Model: IC695CMU310-BC
- Product Series: PACSystems RX3i
- Product Name: Max-ON Hot-Standby Redundancy CPU
- Part Number: IC695CMU310-BC
- Hardware Revision: BC
- Processor Speed: 300 MHz
- User Memory: 10 MB
- Serial Communication: 1 RS-232 port and 1 RS-485 port
- Redundancy Type: Max-ON Hot-Standby
- Backplane Compatibility: RX3i Universal Backplane
- Redundancy Communication: Dedicated Ethernet LAN through compatible Ethernet modules
- Operating Temperature: 0–60°C (32–140°F), subject to installation specifications
- Power Requirements: +3.3 VDC and +5 VDC from the RX3i backplane
- Product Status: Legacy product
- Country of Origin: Verify from the individual unit label
- Dimensions: Confirm from the physical unit
- Weight: Confirm before shipping
Technical Specifications and Features
- 300 MHz Processing Performance
- Provides processing capacity for industrial automation logic and sequential control.
- Supports PACSystems RX3i application programs.
- Designed for demanding control and monitoring tasks.
- Max-ON Hot-Standby Redundancy
- Supports redundant operation using two RX3i controller systems.
- Exchanges operating data through one or two dedicated Ethernet LANs.
- Includes application functions for variable synchronization, program equivalence testing, active-controller selection, and diagnostics.
- Transfer of control is not bumpless; the documented transfer may take two to three CPU logic scans.
- Memory and Program Storage
- Provides 10 MB of user memory.
- Supports battery-backed RAM and non-volatile flash storage.
- Battery condition should be checked to protect retained application data.
- Serial Communication
- One RS-232 communication port.
- One RS-485 communication port.
- Supports serial protocols including SNP and Serial I/O.
- Modbus Master or Slave functions depend on the application program and configuration.
- RX3i System Integration
- Installs in a compatible RX3i Universal Backplane.
- Supports compatible RX3i and selected Series 90-30 expansion equipment.
- Requires compatible Ethernet modules and Max-ON application software for redundant operation.
- Firmware Revision BC
- The IC695CMU310-BC revision is associated with firmware release 3.81.
- Firmware compatibility must be checked against the programming software, installed modules, and system configuration before upgrading or replacing the CPU.
Industrial Applications
- Standby power generation control
- Boiler and auxiliary plant control
- Fuel loading and transfer systems
- Industrial manufacturing automation
- Process control systems
- Critical machinery control
- Legacy RX3i redundant PLC installations
Installation and Commissioning
- Verify the complete catalog number IC695CMU310-BC and inspect the hardware revision label.
- Confirm that the rack is an approved RX3i Universal Backplane.
- Check the power supply model and backplane voltage requirements.
- Install the CPU according to the RX3i hardware installation instructions.
- Verify that the Ethernet modules and dedicated redundancy network are correctly installed.
- Confirm that both redundant controller systems use compatible hardware and firmware.
- Check the battery condition and install an approved battery where required.
- Connect the RS-232 and RS-485 interfaces according to the communication plan.
- Load or verify the Max-ON application software and controller configuration.
- Test synchronization, active/standby status, fault reporting, and transfer of control under controlled conditions before returning the process to service.
Daily Maintenance and Care
- Monitor CPU OK, RUN, SYSTEM FAULT, and battery indicators.
- Check the condition of the CPU backup battery.
- Inspect the backplane and module connections for looseness or contamination.
- Monitor Ethernet communication between the redundant systems.
- Review controller diagnostic messages and fault logs.
- Verify that the active and standby programs remain equivalent.
- Check the RS-232 and RS-485 communication links.
- Maintain a backup of the application program and configuration.
- Record firmware revisions before performing maintenance or upgrades.
Troubleshooting and Common Questions
Q1: What is the IC695CMU310-BC used for?
It is a Max-ON Hot-Standby Redundancy CPU for GE Fanuc PACSystems RX3i systems. It supports redundant controller operation using two separate RX3i systems.
Q2: Does this CPU have built-in Ethernet ports?
The CPU has two built-in serial ports, RS-232 and RS-485. Redundancy communication uses compatible Ethernet modules, such as the IC695ETM001.
Q3: Is the IC695CMU310-BC the same as the IC695CPU310?
No. Both are 300 MHz RX3i CPU products, but the IC695CMU310 is specifically designed for Max-ON hot-standby redundancy. The IC695CPU310 is a standard CPU and is not a direct substitute for the redundant CPU.
Q4: Can one IC695CMU310 operate as a complete redundant system?
No. Max-ON redundancy requires two compatible RX3i systems, the required Ethernet communication hardware, and Max-ON application software.
Q5: Is the redundancy transfer bumpless?
No. Max-ON is a hot-standby architecture, but the documented transfer of control may take two to three CPU logic scans. Application suitability must be evaluated against the process response requirements.
Q6: Can the BC revision be replaced by another IC695CMU310 revision?
Not automatically. Confirm firmware compatibility, application requirements, installed module support, and the system’s approved replacement procedure before substitution.
Safety Precautions
- Back up the application program and configuration before replacing the CPU.
- Follow approved shutdown and isolation procedures before removing the module.
- Do not remove or replace the CPU while the system is operating unless the documented system procedure explicitly permits it.
- Verify firmware and hardware compatibility before downloading or upgrading.
- Test redundant-controller synchronization and transfer behavior before process startup.
- Do not assume Max-ON redundancy provides a certified safety function or SIL rating.
Recommended Related GE Fanuc Models
- IC695CPU310 – PACSystems RX3i 300 MHz standard CPU
- IC695CRU310 – PACSystems RX3i 300 MHz hot-standby redundant CPU
- IC695CRU320 – PACSystems RX3i 1 GHz bumpless redundant CPU
- IC695CPU320 – PACSystems RX3i 1 GHz standard CPU
- IC695ETM001 – RX3i Ethernet Interface Module
- IC695CHS012 – RX3i 12-slot Universal Backplane
- IC695CHS016 – RX3i 16-slot Universal Backplane
- IC695PSA040 – RX3i AC/DC Power Supply
- IC695PSD040 – RX3i 24 VDC Power Supply
- IC695PSA140 – RX3i Multipurpose Power Supply
- IC695PSD140 – RX3i Multipurpose 24 VDC Power Supply
- IC695CMM002 – RX3i Serial Communications Module
- IC695CMM004 – RX3i Serial Communications Module
- IC695ACC302 – RX3i Lithium Smart Battery
- IC695RMX128 – RX3i Redundancy Memory Exchange Module
Note: These are related RX3i system components and CPU models, not universal direct replacements. Verify the exact hardware revision, firmware, backplane, power supply, and redundancy configuration before ordering.