GE | IS200ERRRH1A | EX2100 Exciter Regulator Redundant Relay Board

Product Description

The GE IS200ERRRH1A is an Exciter Regulator Redundant Relay Board designed for the GE EX2100 Excitation Control System. It is used in redundant excitation regulator configurations to support relay transfer and control functions within the excitation system.

The board is associated with the redundant relay arrangement and supports the operation of the K41 and K5T transfer relays. It helps maintain the required relay-control functions in systems designed with redundant excitation regulation.

The IS200ERRRH1A is a printed circuit board assembly featuring relay components, transformers, integrated circuits, and male and female plug connectors. It is intended for maintenance, replacement, and restoration of compatible GE EX2100 excitation control installations.

Product Parameters

  • Brand: General Electric (GE)
  • Model: IS200ERRRH1A
  • Product Name: Exciter Regulator Redundant Relay Board
  • Functional Acronym: ERRR
  • Series: EX2100 Excitation Control
  • Product Type: Relay Control PCB
  • Application: Redundant Excitation Regulator
  • Relay Function: Supports K41 and K5T transfer relay control
  • Connectors: Male and female plug connectors
  • Board Revision: A
  • Operating Mode: Redundant
  • Place of Manufacture: GE Industrial Systems, USA
  • Product Status: Legacy spare part; actual inventory condition to be confirmed
  • Dimensions: Not specified
  • Weight: Not specified
  • Country of Origin: USA (reported; verify individual unit)
  • Power Requirements: Refer to EX2100 system documentation
  • Discontinued: Current lifecycle status to be confirmed

Main Applications

  • GE EX2100 excitation control systems
  • Generator excitation regulator redundancy
  • Excitation regulator relay transfer functions
  • Power plant generator control systems
  • Gas and steam turbine generator installations
  • Industrial generator maintenance and repair
  • Replacement of faulty redundant relay boards

Installation and Commissioning

  1. Verify the complete part number IS200ERRRH1A and revision before installation.
  2. Confirm that the installed system uses the compatible EX2100 redundant regulator architecture.
  3. Review the system wiring diagrams and relay-control configuration.
  4. Follow approved plant isolation and maintenance procedures.
  5. Inspect the board connectors, relays, transformers, and PCB surface for damage.
  6. Install the board in the designated redundant relay assembly or backplane position.
  7. Restore power according to the manufacturer’s procedure.
  8. Check relay status and controller diagnostics.
  9. Verify K41 and K5T transfer relay operation using the approved commissioning procedure.
  10. Confirm redundant regulator status and system alarms before returning the excitation system to service.

Daily Maintenance and Care

  • Monitor redundant regulator and relay status.
  • Review EX2100 diagnostic messages and event records.
  • Inspect connectors for looseness, oxidation, or contamination.
  • Check the PCB for overheating, corrosion, or component damage.
  • Keep the excitation control cabinet clean and properly ventilated.
  • Verify that redundant control paths remain available.
  • Maintain records of board revisions and maintenance activities.

Troubleshooting and Common Problems

  • Board not recognized: Check the board seating, connector condition, and backplane compatibility.
  • Relay transfer fault: Review K41 and K5T control circuits and system diagnostics.
  • Redundancy alarm: Check the redundant regulator configuration and associated hardware.
  • Intermittent relay operation: Inspect connectors, relay components, and control wiring.
  • Unexpected excitation system alarm: Review EX2100 event logs and verify the installed board revision.
  • Replacement board mismatch: Confirm the complete IS200ERRRH1A designation and system configuration.

Safety Precautions

  • Maintenance must be performed by qualified generator excitation or electrical control technicians.
  • Follow the plant’s approved shutdown, isolation, and lockout/tagout procedures.
  • Verify the excitation system’s redundant operating status before removing any board.
  • Do not insert or remove the board under power unless explicitly permitted by the applicable GE documentation.
  • Use ESD protection when handling electronic assemblies.
  • Perform all required relay and redundancy checks before returning the generator to service.

Recommended GE Models and Related Products

The following components belong to or are associated with the GE EX2100 excitation control system. They support different functions and are not direct replacements for IS200ERRRH1A.

  1. IS200ERRBG1A – Exciter Regulator Redundant Backplane.
  2. IS200ERIOH1A – Exciter Regulator I/O Board.
  3. IS200ERDDH1A – Exciter Regulator Dynamics Discharge Board.
  4. IS200EROCH1A – Exciter Regulator Options Card.
  5. IS200ERBPG1A – Exciter Regulator Backplane.
  6. IS200ESELH1A – Exciter Selector Board.
  7. IS200EXHSG3A – Exciter High-Speed Relay Driver Board.
  8. IS200EXAMG1B – Exciter Attenuation Module.
  9. IS200EPCTG1A – Exciter PT/CT Board.
  10. IS200ECTBG1A – Exciter Contact Terminal Board.
  11. IS200EXTBG1A – Exciter Terminal Board.
  12. IS200EDCFH1A – Exciter DC Feedback Board.
  13. IS200EACFH1A – Exciter AC Feedback Board.
  14. IS200EXIBG1A – Exciter Bridge Interface Board.
  15. IS200EPDMG1B – Exciter Power Distribution Module.

Frequently Asked Questions

Q1: What is the GE IS200ERRRH1A used for?

A1: It is an EX2100 Exciter Regulator Redundant Relay Board used in redundant excitation regulator arrangements.

Q2: What does the ERRR designation mean?

A2: ERRR stands for Exciter Regulator Redundant Relay.

Q3: Which relays are associated with this board?

A3: The IS200ERRRH1A is associated with K41 and K5T transfer relay control functions.

Q4: Is this board used in simplex systems?

A4: It is primarily associated with redundant EX2100 regulator configurations. Confirm the required board arrangement using the system drawings.

Q5: Can IS200ERRRH1A replace another ERRR board revision?

A5: Compatibility depends on the complete part number, hardware revision, and system configuration. Verify approved replacement information before substitution.

Q6: What should be checked before ordering?

A6: Confirm the full model number, revision, connector condition, board markings, and compatibility with the installed EX2100 system.