The MMLG01B1AA0001C is a high-speed, self-resetting auxiliary tripping relay from the GEC Alsthom (now GE/Alstom) Midos product line. This relay serves as a crucial interface between low-power protection devices (such as digital relays or earth fault sensors) and high-energy circuit breaker trip coils. By providing high-speed operation and robust contact ratings, it ensures that the circuit breaker operates reliably when a fault is detected.
⚙️ Product Parameters
-
Product Name: MMLG01 Auxiliary Tripping Relay
-
Part Number: MMLG01B1AA0001C
-
Series: Midos (Modular Integrated Draw-out System)
-
Function: High-speed interposing/tripping
-
Operating Time: Extremely fast (typically <10ms)
-
Mounting: Standard Midos draw-out case
-
Contact Arrangement: Multiple heavy-duty contacts
-
Operating Temperature: -25°C to +55°C
-
Weight: Approx. 0.85 kg
-
Country of Origin: UK
🏭 Application Fields
-
Protection Scheme Interposing (Breaker Tripping)
-
Substation Logic Interlocking
-
Signal Multiplication for SCADA/Monitoring
-
Emergency Shutdown (ESD) Systems
-
Protection Scheme Supervision
🛠️ Product Usage Guide
1. Wiring & Installation The MMLG01 is a modular device designed for use within the Midos rack system. It provides electrical isolation between the protection relay’s sensitive circuitry and the high-current trip circuit of the breaker.
2. Maintenance & Testing
-
Contact Integrity: The contacts are designed for high-current pulse applications. While durable, you should inspect them for arc wear if the relay has performed thousands of operations.
-
Functional Test: Apply the nominal DC auxiliary voltage to the coil terminals. The relay should operate decisively and instantly. Use a relay test set to measure the exact operating time if your protection coordination study requires strict timing tolerances.
3. Initial Operation Checklist
-
✅ Verify Voltage: Ensure the auxiliary voltage (e.g., 110V DC or 220V DC) matches the relay coil rating perfectly.
-
✅ Check Polarity: While these relays are generally robust, confirm the polarity of the DC coil connection if a suppression diode is present.
-
✅ Secure Terminals: Ensure the draw-out unit is fully inserted and the latching screws are tightened to guarantee a solid connection to the backplane.
-
✅ Grounding: Confirm the relay case is properly grounded to the substation earth bus to ensure safety.
❓ FAQ (Q&A)
Q: Is the MMLG01B1AA0001C a latching relay? A: No, the MMLG01 series is a non-latching, self-resetting relay. The contacts will return to their original position as soon as the signal to the coil is removed. If your application requires the trip to be held until a manual reset, you would require the MMLG02 (latching) version.
Q: Why is an interposing relay necessary? A: Most digital or static protection relays have output contacts that can handle small amounts of current (e.g., 5-10A for short durations). The trip coils of large circuit breakers often have high inrush currents or require higher voltage/current capabilities; the MMLG01 handles this heavy-duty load, protecting the sensitive protection relay from damage.
📋 Recommended Related Models
-
MMLG02 (Latching Version)
-
MMLG03 (Low-current sensitive version)
-
MVAX Series (Alternate tripping relay series)
-
Midos Case Accessories
-
GEC Alsthom Trip Relay Supervision Unit
-
MMLG01 Spare Case
-
Midos Rack Mounting Kit
-
Auxiliary Tripping Relay Supervision Unit
-
081798J (Direct part number cross-reference)
-
GEC Alsthom VAGM Auxiliary Relay