GEC Alsthom | MMLG01B1AA0001C Tripping Relay

The MMLG01B1AA0001C is a high-speed, self-resetting auxiliary tripping relay from the GEC Alsthom (now GE/Alstom) Midos product line. This relay serves as a crucial interface between low-power protection devices (such as digital relays or earth fault sensors) and high-energy circuit breaker trip coils. By providing high-speed operation and robust contact ratings, it ensures that the circuit breaker operates reliably when a fault is detected.

⚙️ Product Parameters

  • Product Name: MMLG01 Auxiliary Tripping Relay

  • Part Number: MMLG01B1AA0001C

  • Series: Midos (Modular Integrated Draw-out System)

  • Function: High-speed interposing/tripping

  • Operating Time: Extremely fast (typically <10ms)

  • Mounting: Standard Midos draw-out case

  • Contact Arrangement: Multiple heavy-duty contacts

  • Operating Temperature: -25°C to +55°C

  • Weight: Approx. 0.85 kg

  • Country of Origin: UK

🏭 Application Fields

  • Protection Scheme Interposing (Breaker Tripping)

  • Substation Logic Interlocking

  • Signal Multiplication for SCADA/Monitoring

  • Emergency Shutdown (ESD) Systems

  • Protection Scheme Supervision

🛠️ Product Usage Guide

1. Wiring & Installation The MMLG01 is a modular device designed for use within the Midos rack system. It provides electrical isolation between the protection relay’s sensitive circuitry and the high-current trip circuit of the breaker.

2. Maintenance & Testing

  • Contact Integrity: The contacts are designed for high-current pulse applications. While durable, you should inspect them for arc wear if the relay has performed thousands of operations.

  • Functional Test: Apply the nominal DC auxiliary voltage to the coil terminals. The relay should operate decisively and instantly. Use a relay test set to measure the exact operating time if your protection coordination study requires strict timing tolerances.

3. Initial Operation Checklist

  • ✅ Verify Voltage: Ensure the auxiliary voltage (e.g., 110V DC or 220V DC) matches the relay coil rating perfectly.

  • ✅ Check Polarity: While these relays are generally robust, confirm the polarity of the DC coil connection if a suppression diode is present.

  • ✅ Secure Terminals: Ensure the draw-out unit is fully inserted and the latching screws are tightened to guarantee a solid connection to the backplane.

  • ✅ Grounding: Confirm the relay case is properly grounded to the substation earth bus to ensure safety.

❓ FAQ (Q&A)

Q: Is the MMLG01B1AA0001C a latching relay? A: No, the MMLG01 series is a non-latching, self-resetting relay. The contacts will return to their original position as soon as the signal to the coil is removed. If your application requires the trip to be held until a manual reset, you would require the MMLG02 (latching) version.

Q: Why is an interposing relay necessary? A: Most digital or static protection relays have output contacts that can handle small amounts of current (e.g., 5-10A for short durations). The trip coils of large circuit breakers often have high inrush currents or require higher voltage/current capabilities; the MMLG01 handles this heavy-duty load, protecting the sensitive protection relay from damage.

📋 Recommended Related Models

  1. MMLG02 (Latching Version)

  2. MMLG03 (Low-current sensitive version)

  3. MVAX Series (Alternate tripping relay series)

  4. Midos Case Accessories

  5. GEC Alsthom Trip Relay Supervision Unit

  6. MMLG01 Spare Case

  7. Midos Rack Mounting Kit

  8. Auxiliary Tripping Relay Supervision Unit

  9. 081798J (Direct part number cross-reference)

  10. GEC Alsthom VAGM Auxiliary Relay

Share this story: