Product Description
The Johnson Controls MS-MIG3520-0 Rev AB is a Metasys Integrator device designed for building automation system integration. It belongs to the Johnson Controls Metasys product family and is used to facilitate communication between compatible third-party building equipment and a Metasys supervisory control system.
Metasys Integrator products provide an interface between building automation networks and external equipment, allowing supported system data to be exchanged with the building management platform. Depending on the installed integration protocol and configuration, this can support centralized monitoring, equipment status reporting, and control functions.
The MS-MIG3520-0 is a legacy building automation component. Before replacement or installation, verify the complete model number, revision, communication protocol, supported equipment, and Metasys software compatibility.

Product Datasheet & Parameters
- Brand: Johnson Controls
- Model: MS-MIG3520-0
- Revision: Rev AB
- Product Name: Metasys Integrator
- Product Series: Metasys Building Automation
- Product Type: Building Automation Integration Device
- Main Application: Integration of compatible third-party equipment with Metasys systems
- Communication Protocol: Depends on the installed integration configuration; verify documentation
- Network Interface: Confirm from the physical unit and technical documentation
- Software Compatibility: Depends on Metasys release and integration configuration
- Place of Manufacture: Not confirmed
- Product Status: Confirm actual condition before purchase
- Dimensions: Not confirmed
- Weight: Not confirmed
- Country of Origin: Not confirmed
- Power Requirements: Verify the unit’s nameplate and installation documentation
- Discontinued: Legacy product; current support and availability should be confirmed
Main Features & Applications
- Designed for integration with Johnson Controls Metasys building automation systems.
- Provides an interface between compatible third-party equipment and the supervisory system.
- Supports centralized monitoring of connected building equipment.
- Enables data exchange between supported field devices and Metasys.
- Helps integrate equipment from different manufacturers into a common building management environment.
- Suitable for maintenance and restoration of legacy building automation installations.
Typical application areas include HVAC control, building equipment monitoring, plant-room integration, and centralized facility management. Actual supported functions depend on the installed protocol and configuration.
Installation & Commissioning
- Confirm the complete MS-MIG3520-0 model number and Rev AB hardware revision.
- Identify the existing Metasys system version and the associated integration application.
- Verify the supported communication protocol and the third-party equipment interface.
- Isolate power before connecting or removing the device.
- Inspect terminals, connectors, wiring, and enclosure condition.
- Connect the communication network according to the approved wiring diagram.
- Configure device addressing, communication parameters, and integration points using the appropriate documentation.
- Verify data exchange between the integrator and the Metasys supervisory system.
- Test monitoring points, status indications, alarms, and authorized control functions.
- Document the configuration and confirm normal operation before handing the system back to the building operator.
Do not assume that the MS-MIG3520-0 supports every Metasys communication protocol. Confirm the exact integration application before commissioning.
Daily Maintenance
- Check the device for normal power and communication status.
- Monitor Metasys for communication failures and offline equipment points.
- Inspect communication wiring and terminal connections.
- Check for abnormal heating, dust accumulation, or moisture.
- Review network diagnostics and integration error messages.
- Back up configuration files and point mappings where supported.
- Record firmware, software, and hardware revision details.
- Verify connected equipment status during scheduled building automation inspections.
Troubleshooting & Frequently Asked Questions
Q1: What is the Johnson Controls MS-MIG3520-0?
A: It is a Metasys Integrator device used to connect compatible third-party equipment with a Johnson Controls building automation system.
Q2: What does Rev AB mean?
A: Rev AB identifies the hardware revision shown in the product listing. Compatibility should be checked against the revision installed in the existing system.
Q3: Can this device integrate with any third-party controller?
A: No. Integration depends on the supported communication protocol, driver, device configuration, and Metasys software version.
Q4: Can it be used with a newer Metasys system?
A: Compatibility must be verified against the relevant Metasys release and integration documentation. Legacy hardware may have software or driver limitations.
Q5: What should be checked before purchasing?
A: Confirm the MS-MIG3520-0 model, Rev AB marking, connector condition, power requirements, communication interfaces, and intended integration application.
Q6: What causes a communication failure?
A: Possible causes include incorrect network addressing, wiring faults, incompatible protocol settings, configuration errors, or a problem with the connected equipment.
Safety Precautions
- Disconnect power before performing electrical connections.
- Follow the manufacturer’s grounding and wiring requirements.
- Do not apply an unverified supply voltage.
- Confirm network polarity and terminal assignments before connection.
- Back up existing integration configurations before making changes.
- Do not enable control points until their operation has been verified.
- Use qualified building automation technicians for installation and commissioning.
Recommended Johnson Controls Models & Related Products
The following are related Johnson Controls Metasys products and building automation components, not confirmed direct replacements for MS-MIG3520-0.
- Johnson Controls MS-MIG3520-0 – Metasys Integrator
- Johnson Controls Metasys NAE – Network Automation Engine
- Johnson Controls NAE55 – Network Automation Engine
- Johnson Controls NAE85 – Network Automation Engine
- Johnson Controls NIE – Network Integration Engine
- Johnson Controls NCE – Network Control Engine
- Johnson Controls FX80 – Supervisory Controller
- Johnson Controls FX60 – Supervisory Controller
- Johnson Controls FEC Series – Field Equipment Controllers
- Johnson Controls FAC Series – Field Advanced Controllers
- Johnson Controls VMA Series – Variable Air Volume Controllers
- Johnson Controls CGM Series – General Purpose Controllers
- Johnson Controls CVM Series – VAV and Terminal Unit Controllers
- Johnson Controls Metasys ADS – Application and Data Server
- Johnson Controls Metasys ADX – Extended Application and Data Server