KONGSBERG AUTRONICA | EA-300/KR | Microcomputer Processor Unit

The Kongsberg Autronica EA-300/KR is a high-reliability microcomputer processor unit designed for critical marine, offshore, and industrial monitoring systems. Engineered for real-time data acquisition, signal processing, and system supervision, it serves as a central control and processing module within Autronica engine monitoring, fire detection, and alarm automation networks.

Built with marine-grade hardware and protective housing, the EA-300/KR delivers exceptional vibration resistance, electromagnetic compatibility (EMI) immunity, and operational stability under demanding shipboard environments. It features integrated communication interfaces and multi-channel I/O processing capabilities to maintain continuous, deterministic system operation.

Kongsberg Autronica EA-300/KR Microcomputer Processor Unit (Used) Image 1 of 4

Parameter Specification Value / Feature Details
Brand Kongsberg / Autronica
Model EA-300/KR
Series EA System Hardware Series
Product Name Microcomputer Processor Unit
Country of Origin Norway
Product Status Active / Available
Dimensions (H x W x D) 240 mm x 120 mm x 160 mm
Weight 1.85 kg (4.08 lbs)
Operating Supply Voltage 24 V DC (18 to 32 V DC) / < 18 W
Operating Temperature -15°C to +70°C (+5°F to +158°F)

✔ Visual Check: Inspect the outer housing, card-edge connectors, and mounting brackets for physical impact, salt-air corrosion, or transit damage before installation.

✔ Rack & Enclosure Mounting: Secure the processor unit into the target sub-rack or cabinet slot using marine-rated vibration damping mounts and retention screws.

✔ Grounding Verification: Ensure a low-impedance copper grounding strap connects the chassis earth terminal directly to the vessel panel ground bus to maximize noise immunity.

✔ Power Supply Check: Verify 24 V DC auxiliary supply lines with a multimeter to confirm voltage levels remain within the 18–32 V DC operating window prior to powering on.

✔ Communication & Link Diagnostic: Power up the system and monitor front-panel status LEDs to confirm processor initialization and normal communication loop activity.

◆ Dust & Moisture Mitigation: Periodically clear dust accumulation from ventilation grilles using clean, dry compressed air; maintain cabinet seals to prevent salt-fog entry.

◆ Terminal & Connector Inspection: Inspect rear terminal block screws and bus cable connectors during scheduled vessel maintenance turnarounds to ensure tight connections against engine vibration.

◆ Battery & Memory Care: Inspect onboard RTC/CMOS backup batteries periodically and replace them per manufacturer schedules to preserve real-time clock and log settings.

◆ Software Project Backups: Maintain up-to-date offline backups of system parameter settings, alarm thresholds, and firmware configurations on service laptops.

⚠ Processor System Fault / Hardware Alarm LED Active

Check auxiliary input voltage levels. If power is normal, isolate power, unseat the unit, clean edge contacts, and re-seat firmly into the rack slot.

⚠ Communication Link Timeout / Loop Isolation

Inspect serial or fieldbus connection wiring for loose terminal screws or broken wire shielding. Verify that end-of-line termination resistors are correctly placed.

⚠ Configuration / Memory Loss on Boot

Replace internal system backup batteries and re-download configuration parameters from the engineering workstation.

⚠ De-energize Before Handling: Turn off system supply power before connecting or disconnecting terminal blocks or pulling the processor unit from its slot.

⚠ Electrostatic Discharge (ESD) Protection: Wear a grounded anti-static wrist strap when handling the unit or touching exposed backplane connectors to protect sensitive CMOS logic circuits.

⚠ Vibration Lock Requirement: Always ensure front panel retaining screws are completely tightened to prevent vibration-induced contact separation during vessel operation.

⚠ Voltage Limits: Operate the unit strictly within the 18–32 V DC power range to prevent damage to internal DC-DC converter circuits.

? Q: What is the primary application of the Kongsberg Autronica EA-300/KR unit?

A: It is designed as a central microcomputer processing module for marine automation, engine monitoring, alarm monitoring, and safety shutdown systems.

? Q: Does the EA-300/KR support marine classification society standards?

A: Yes, it is engineered to satisfy strict type-approval requirements (such as DNV, ABS, and LR) for marine and offshore cabinet environments.

? Q: Can the EA-300/KR be replaced without re-configuring external sensor wiring?

A: Yes, field terminal blocks and bus connectors disconnect directly from the unit casing, allowing drop-in replacement without re-wiring sensor channels.

? Q: Does the unit require specialized software for system diagnostics?

A: Basic status and channel faults are displayed via onboard LEDs, while detailed diagnostic traces and parameter adjustments can be accessed using Autronica system service tools.

Share this story: