  • Product Description

    The ABB AIM0016 is an analog measurement input module designed for ABB Relion protection and control relay platforms. It receives current signals from external current transformers (CTs) and supplies measurement data to the relay’s protection, metering, and monitoring functions.

    ABB documentation identifies the AIM16 module variant as having four current-transformer inputs with selectable nominal ratings of 1 A or 5 A. These inputs are used to acquire phase and residual current measurements for electrical protection applications.

    The module is associated with ABB Relion relay configurations, including REF615 and other compatible relay variants. Its actual application depends on the relay model, hardware configuration, and installed slot.

    Important identification note: AIM0016 is an analog current measurement module, not a 16-channel digital input module. Supplier listings show several associated order-code variations, including 2RCA007128A0001J and 2RCA007120H. Verify the complete part number and revision on the physical label before ordering.

    Product Parameters

    • Brand: ABB
    • Model: AIM0016
    • Product Name: Analog Current Measurement Input Module
    • Product Family: ABB Relion Protection and Control
    • Module Type: AIM16 Analog Input Module
    • Input Type: Current Transformer (CT)
    • Number of CT Inputs: 4
    • Nominal Input Current: 1 A / 5 A
    • Input Configuration: Current measurement inputs
    • Application: Protection, measurement, and monitoring
    • Compatible Platform: Specified ABB Relion relay configurations
    • Example Relay Family: REF615
    • Installation: Dedicated relay module slot
    • Communication: Internal relay backplane
    • Auxiliary Power: Supplied through the compatible relay assembly; verify relay requirements
    • Dimensions: Not confirmed for the standalone module
    • Weight: Not confirmed
    • Country of Origin: Not confirmed
    • Product Status: Verify by complete order code
    • Discontinued: Not confirmed

    Main Features

    • Four CT Measurement Inputs: Acquires current signals from external current transformers.
    • 1 A / 5 A Compatibility: Supports the documented nominal CT secondary input ratings.
    • Protection Relay Integration: Provides current measurement signals to compatible ABB Relion relay functions.
    • Electrical Protection Applications: Supports current-based protection and monitoring functions when configured in the relay.
    • Compact Modular Design: Installed as part of the relay’s internal hardware assembly.
    • Configurable Relay Application: Measurement inputs are used according to the relay’s protection functions and engineering configuration.

    Installation and Commissioning

    1. Verify the complete AIM0016 order code, hardware revision, and relay compatibility.
    2. Confirm that the receiving relay supports the AIM16 module and the intended slot.
    3. Check the CT secondary rating and ensure it matches the selected 1 A or 5 A input configuration.
    4. Isolate the equipment and follow the plant’s electrical safety and switching procedures.
    5. Before disconnecting any CT wiring, ensure that CT secondary circuits are safely shorted using approved test facilities. Never leave an energized CT secondary open-circuited.
    6. Inspect connectors, terminal blocks, and module contacts for damage or contamination.
    7. Install the module according to ABB relay installation instructions.
    8. Check phase identification, CT polarity, wiring continuity, and residual-current connections.
    9. Configure the corresponding measurement and protection settings using the supported ABB engineering software.
    10. Perform secondary injection tests and verify current measurements, phase relationships, and protection responses before returning the relay to service.

    Daily Maintenance and Care

    • Check relay self-supervision and module diagnostic indications.
    • Review current measurements for abnormal values or phase imbalance.
    • Inspect CT terminal connections during scheduled maintenance.
    • Check for loose wiring, corrosion, and damaged insulation.
    • Verify CT polarity and phase identification after maintenance work.
    • Review event records and protection alarms for measurement-related faults.
    • Keep the relay cabinet clean, dry, and within the specified environmental limits.
    • Maintain accurate records of module revisions and relay configuration changes.

    Troubleshooting and Common Questions

    Q1: What is the function of ABB AIM0016?

    It is an analog current measurement input module that receives CT signals for compatible ABB Relion protection and control relays.

    Q2: How many inputs does AIM0016 have?

    ABB documentation identifies four CT inputs for the AIM16 variant.

    Q3: Does AIM0016 support 1 A and 5 A CT signals?

    Yes. The documented AIM16 variant supports nominal CT input ratings of 1 A and 5 A. The correct configuration must match the connected CT secondary rating.

    Q4: Is AIM0016 a digital input module?

    No. It is an analog current measurement module. Supplier descriptions identifying it as a digital input module or a 16-channel analog input card are inconsistent with ABB’s module documentation.

    Q5: Can AIM0016 replace AIM0006?

    Not automatically. These are different analog input module variants. Their input arrangements and relay hardware configurations must be checked before replacement.

    Q6: Why are current measurements incorrect?

    Possible causes include incorrect CT ratio settings, reversed CT polarity, phase wiring errors, loose terminals, incorrect nominal input selection, or a module fault. Check the complete measurement circuit and relay configuration.

    Q7: Can AIM0016 be used with any ABB Relion relay?

    No. Compatibility depends on the relay model, hardware generation, slot assignment, and approved module configuration. Confirm the exact relay documentation before installation.

    Recommended Related ABB Models

    The following are related ABB Relion measurement modules and protection relay products. They are not all direct replacements for AIM0016.

    1. AIM0006 – Analog Measurement Input Module
    2. AIM0015 – Analog Measurement Input Module
    3. AIM0017 – Analog Measurement Input Module
    4. AIM0018 – Analog Measurement Input Module
    5. AIM0019 – Analog Measurement Input Module
    6. AIM3 – Analog Input Module
    7. AIM4 – Analog Input Module
    8. AIM5 – Analog Input Module
    9. AIM6 – Analog Input Module
    10. REF615 – Feeder Protection and Control Relay
    11. REF620 – Feeder Protection and Control Relay
    12. REU615 – Voltage Protection and Control Relay
    13. REM615 – Motor Protection and Control Relay
    14. RET615 – Transformer Protection and Control Relay
    15. REX615 – Protection and Control Relay

    Safety Precautions

    • Confirm the exact module order code and relay compatibility before installation.
    • Never open-circuit an energized CT secondary.
    • Verify CT ratio, polarity, phase identification, and wiring before commissioning.
    • Do not change protection settings without authorization and an approved engineering procedure.
    • Perform secondary injection and protection-function testing before returning equipment to service.
    • Installation and maintenance must be performed by qualified electrical protection personnel.