Product code: N/A
Allestec | 800-1443D | Onguard 800 Fire Suppression Release Module
¥99,999.00 Original price was: ¥99,999.00.¥5,652.00Current price is: ¥5,652.00.
This image and price are not for reference. If you need to inquire, please contact me!
🌍Country of origin: USA France Germany Estonia Norway UK
⌚Delivery date: in stock
🛠After-sales service: brand new with one year warranty
⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen
🕰Warranty: 12 months/365 days
☎️ Please contact me: 15359029662 Ms. Amy Sun
📎Chinese official website: www.dcsplcabb.com
📩Email: geabbamy@gmail.com
💬Whatsapp: +86 15359029662
If you have any products that you cannot find, you can consult anytime.
Detailed content
Product Overview
The Allestec 800-1443D Release Module is a dedicated release-control module for the Onguard 800 Series industrial gas and fire safety control panel. It manages the timed activation of electrically operated fire-suppression release solenoids, supporting either a single suppression tank or a main-and-reserve tank configuration.
The module provides programmable release delays, an inhibit function for system testing, abort functionality, and monitoring of release-circuit conditions. An auxiliary discharge relay provides a status signal when the main release sequence is activated.
This module is designed for use in fire and gas suppression systems where controlled discharge and system supervision are essential. It should be installed, configured, and tested by qualified fire-safety personnel in accordance with the applicable system manual.
The listed unit is identified by serial number 80018419. The seller describes its condition as new; confirm the actual condition and testing documentation before purchase.
Key Features
- Manufacturer: Allestec
- Model: 800-1443D
- System: Onguard 800 Series gas and fire safety panel
- Supports single-tank or main-and-reserve suppression configurations
- Two independently adjustable digital release timers
- Two independently controlled release-solenoid circuits
- Inhibit mode for system testing
- Configurable abort function
- Auxiliary SPDT discharge relay
- Supervised release circuits with individual fusing
- Non-volatile storage for programmed configuration data
- Designed for installation in a compatible Onguard 800 system rack
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Allestec |
| Model | 800-1443D |
| Series | Onguard 800 |
| Product Name | Fire Suppression Release Module |
| Module Function | Timed release control |
| Serial Number | 80018419 |
| Operating Voltage | 20–28 V DC |
| Nominal Supply | 24 V DC |
| Quiescent Current | 70 mA |
| Alarm Current | 107 mA, no load |
| Release Outputs | Two independent solenoid circuits |
| Solenoid Output Rating | 24 V DC, up to 4 A per circuit |
| Main Release Timer | Adjustable from 0.1 to 9.9 minutes |
| Reserve Release Timer | Adjustable from 0.2 to 9.9 minutes |
| Auxiliary Relay | SPDT dry contact |
| Auxiliary Relay Rating | 5 A at 30 V DC resistive or 250 V AC, subject to applicable specifications |
| Abort Function | Configurable 24 V DC output during countdown |
| Operating Temperature | -17°C to +65°C |
| Operating Humidity | Up to 90%, non-condensing |
| Dimensions | Approximately 1.04 × 3.46 × 6.4 in (W × H × D) |
| Weight | Approximately 4 oz (113 g) |
| Country of Origin | United States, as stated in the seller listing |
| Product Condition | Listed as New – Open Box; verify with seller |
| Discontinued Status | Not confirmed |
Typical Applications
- Industrial gas fire suppression systems
- Automatic fire-extinguishing control panels
- Main and reserve suppression-tank release control
- Industrial plant fire and gas safety systems
- Legacy Onguard 800 system maintenance
- Replacement of a compatible 800-1443 or 800-1443D release module
Frequently Asked Questions
Q1: What is the function of the Allestec 800-1443D?
It controls the timed electrical release of compatible fire-suppression solenoids following an activation signal from the Onguard 800 system.
Q2: Can it control two suppression tanks?
Yes. It supports a main-and-reserve arrangement with separate adjustable timing sequences. It can also be configured for a single-tank application.
Q3: What is the operating voltage?
The approved operating range is 20–28 V DC, with 24 V DC nominal supply.
Q4: Is the 800-1443D compatible with the older 800-1443?
Allestec documentation identifies the 800-1443D as functionally equivalent to the earlier 800-1443 for rack-slot replacement. However, the inhibit function differs, and the 800-1443D adds a discharge relay output. Verify wiring and configuration before substitution.
Q5: What is the purpose of the inhibit function?
It allows authorized personnel to test the system without activating the suppression solenoids. Follow the manufacturer’s prescribed testing procedures.
Q6: What should be checked before ordering?
Confirm the complete part number, serial number, module condition, terminal connections, configuration, and compatibility with the installed Onguard 800 panel.
Q7: Are there any special installation precautions?
Yes. Incorrect wiring or testing can cause unintended suppression-agent discharge. Qualified personnel should follow the manufacturer’s manual and isolate the release solenoids as instructed during commissioning and testing.
Related Allestec Onguard 800 Modules
The following modules belong to the same or a related Onguard 800 system family. They serve different functions and are not direct replacements for the 800-1443D unless specifically approved.
- 800-1440 – Input Module
- 800-1441 – Manual Pull Module
- 800-1442 – Alarm Module
- 800-1443 – Earlier Release Module
- 800-1444 – Fault Module
- 800-1530 – Input Vote Module
- 800-1760 – Relay Module
- 800-2800 – Water Mist Release Module
- 800-1186 – Onguard 800 System Manual
- 800-1211 – End-of-line resistor accessory
- 800-1378 – Test switch rod accessory
- Onguard 800 control-panel assemblies
- Onguard 800 system backplanes and rack components
- Compatible fire-detection input modules
- Compatible suppression-system monitoring and interface modules
Ordering Information
When requesting a quotation, specify Allestec 800-1443D Release Module, serial number 80018419, and the required quantity.
Confirm the condition, functional-test results, included accessories, warranty, and compatibility with the existing Onguard 800 panel before purchase. Because this is a fire-suppression release component, installation and commissioning should be performed by qualified personnel following the applicable manufacturer documentation.