Product code: N/A
GE IS200ESELH2A | Exciter Selector Board
¥99,999.00 Original price was: ¥99,999.00.¥1,588.00Current price is: ¥1,588.00.
This image and price are not for reference. If you need to inquire, please contact me!
🌍Country of origin: USA France Germany Estonia Norway UK
⌚Delivery date: in stock
🛠After-sales service: brand new with one year warranty
⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen
🕰Warranty: 12 months/365 days
☎️ Please contact me: 15359029662 Ms. Amy Sun
📎Chinese official website: www.dcsplcabb.com
📩Email: geabbamy@gmail.com
💬Whatsapp: +86 15359029662
If you have any products that you cannot find, you can consult anytime.
Detailed content
Product Description
The GE IS200ESELH2A / IS200ESELH2AAA is an Exciter Selector Board used in GE EX2100 excitation and Mark VI control systems. The ESEL is a rack-mounted control board that receives six logic-level gate pulse signals from the associated EMIO master I/O board and routes the excitation gating commands toward the EGPA gate pulse amplifier boards. The H2 configuration incorporates three bridge drivers for controlling up to three Power Conversion Modules (PCMs), making it applicable to multi-bridge excitation configurations. In redundant systems, ESEL boards can be arranged with the applicable M1/M2 control architecture. The complete IS200ESELH2AAA part number should be matched with the original installation before replacement.
Product Datasheet
| Specification | Details |
|---|---|
| Brand | General Electric (GE) |
| Model | IS200ESELH2A |
| Full Part Number | IS200ESELH2AAA |
| Series | EX2100 / Mark VI |
| Functional Acronym | ESEL |
| Product Name | Exciter Selector Board |
| Product Type | Excitation Gate Pulse Selector / Routing PCB |
| Primary Application | Static Excitation Control |
| ESEL Configuration | H2 |
| Bridge Drivers | 3 |
| Power Conversion Modules | Up to 3 PCMs |
| Gate Pulse Inputs | 6 logic-level signals from EMIO |
| Output Interface | EGPA gate pulse amplifier boards |
| Backplane Connectors | P1 and P2 |
| Front Indicators | Power, Session, and Gating status LEDs |
| Mounting | GE control rack |
| Redundancy | Supports applicable redundant ESEL configurations |
| System | GE EX2100 / Mark VI |
| Condition | Verify actual item condition before purchase |
| Discontinued Status | Legacy component; verify current system support |
Functional Features
⚙️ Exciter Pulse Selection: The ESEL receives six logic-level gate pulse signals from the associated EMIO board and distributes the selected commands to the excitation power-conversion section.
⚙️ Three-Bridge H2 Configuration: The H2 version contains three bridge drivers and is designed for applications involving up to three Power Conversion Modules.
⚙️ EGPA Interface: Output pulse signals are routed through cable connections to the Exciter Gate Pulse Amplifier (EGPA) boards located in the power conversion cabinet.
⚙️ Redundant Control: In applicable redundant architectures, two ESEL boards can be used with M1 and M2 controllers, while the control architecture determines which ESEL is active.
⚙️ Status Monitoring: Three front-panel LEDs provide power, session, and gating status information.
⚙️ Rack-Mounted Design: The board interfaces with the control rack through P1 and P2 connectors.
FAQ
Q: What is the GE IS200ESELH2A used for?
A: It is an Exciter Selector Board used in GE EX2100 excitation systems to route and select gate pulse commands for the excitation power-conversion section.
Q: What does the H2 designation mean?
A: The H2 configuration uses three bridge drivers and supports control of up to three Power Conversion Modules in applicable EX2100 configurations.
Q: What is the relationship between ESEL and EMIO?
A: The ESEL receives logic-level gate pulse signals from the associated EMIO master I/O board and routes the selected excitation commands toward the EGPA boards.
Q: What are the main connectors on the board?
A: The board uses P1 and P2 backplane connectors.
Q: Can IS200ESELH2AAA replace another ESEL board?
A: Replacement should be based on the complete part number and ESEL configuration. H1, H2, and H3 versions have different bridge-driver capacities, so they should not be treated as interchangeable without verifying the system design.
Q: How many ESEL boards are used in a redundant system?
A: Applicable redundant configurations can use two ESEL boards, with the control architecture selecting the active board.
Troubleshooting & Safety
🛠️ No gating output: Check the EMIO gate-pulse inputs, P1/P2 connections, ESEL status LEDs, and EGPA cable connections.
🛠️ Session LED abnormal: Check the associated control-system connections and active controller status before replacing the ESEL.
🛠️ Intermittent excitation gating: Inspect the board connectors and EGPA harnesses for loose connections, contamination, or mechanical damage.
🛠️ One bridge does not respond: Check the corresponding ESEL bridge-driver path and downstream EGPA/PCM circuitry.
🛠️ Redundant system issue: Verify the M1/M2 controller status and confirm that only the intended ESEL is active according to the system architecture.
⚠️ Excitation systems contain hazardous electrical energy and can generate dangerous field and DC-link voltages.
⚠️ De-energize and isolate the excitation system before removing or installing the board.
⚠️ Follow the approved GE EX2100 shutdown, lockout/tagout, and discharge procedures.
⚠️ Use ESD protection when handling the PCB.
⚠️ Do not change excitation gating, redundancy, or control configuration without qualified personnel and the applicable system documentation.
Recommended GE Models
- IS200ESELH1A — EX2100 Exciter Selector Board, Single-Bridge Configuration
- IS200ESELH2A — EX2100 Exciter Selector Board, Three-Bridge Configuration
- IS200ESELH3A — EX2100 Exciter Selector Board, Six-Bridge Configuration
- IS200ESELH2AAA — EX2100 Exciter Selector Board
- IS200EGPAH1A — EX2100 Exciter Gate Pulse Amplifier Board
- IS200EGDMH1A — EX2100 Exciter Ground Detector Module
- IS200EXHSG3A — EX2100 Excitation Interface Board
- IS200EACFG2A — EX2100 Application Control Board
- IS200EMIOH1A — EX2100 Main I/O Board
- IS200DSPXH1A — Digital Signal Processor Board
- IS200VCRCH1B — Mark VI VCRC Control Board
- IS200VSVOH1B — Mark VI Servo Control Board
- IS200VGENH1B — Mark VI Generator Control Board
- IS200TGENH1A — Mark VI Generator Monitor Terminal Board
- IS200CABPG1BAA — Mark VI VME Control Board