Product code: N/A
GE | IS2020RKPSG3A Rev FFN | Mark VI VME Rack Power Supply Module
¥99,999.00 Original price was: ¥99,999.00.¥5,652.00Current price is: ¥5,652.00.
This image and price are not for reference. If you need to inquire, please contact me!
🌍Country of origin: USA France Germany Estonia Norway UK
⌚Delivery date: in stock
🛠After-sales service: brand new with one year warranty
⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen
🕰Warranty: 12 months/365 days
☎️ Please contact me: 15359029662 Ms. Amy Sun
📎Chinese official website: www.dcsplcabb.com
📩Email: geabbamy@gmail.com
💬Whatsapp: +86 15359029662
If you have any products that you cannot find, you can consult anytime.
Detailed content
Product Overview
The GE IS2020RKPSG3A is a VME Rack Power Supply Module designed for the GE Mark VI Speedtronic turbine control system. It supplies regulated DC power to compatible control and interface rack components, supporting the operation of turbine control hardware in power-generation and industrial applications.
The module provides multiple DC power outputs for rack-level electronics, including +5 V, ±12 V, ±15 V, and +28 V DC rails. It also provides +28 V power outputs and status-monitoring functionality for supported rack configurations. A front-panel switch and LED indicators assist with power control and fault diagnosis.
The listed unit is identified as Revision FFN. Since revision markings and configuration details can affect compatibility, verify the complete nameplate, input-voltage version, rack arrangement, and connector configuration before ordering.
Key Features
- Designed for GE Mark VI Speedtronic turbine control systems
- VME rack power supply module
- Rated output power of approximately 400 W
- Nominal 125 V DC input for the applicable version
- Multiple regulated DC output rails
- +28 V DC power outputs for compatible rack loads
- Status ID output for power-supply monitoring
- Front-panel power switch and status LEDs
- Metal heat-sink construction
- Designed for mounting beside compatible VME control and interface racks
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | General Electric (GE) |
| Model | IS2020RKPSG3A |
| Revision | FFN, as stated in the listing |
| Series | Mark VI Speedtronic |
| Product Name | VME Rack Power Supply Module |
| Functional Acronym | RKPS |
| Input Voltage | 125 V DC for the applicable version; verify nameplate |
| Rated Output Power | Approximately 400 W |
| Output Rails | +5 V, +12 V, -12 V, +15 V, -15 V, and +28 V DC, depending on configuration |
| +28 V Outputs | One remote +28 V PSA output and five additional +28 V PSA outputs, as documented for the model family |
| Status Monitoring | Status ID output and front-panel LED indicators |
| Installation | Mounts on the side of a compatible VME control rack |
| Cooling | Heat-sink-assisted thermal dissipation |
| Compatible Platform | GE Mark VI turbine control system |
| Dimensions | Verify from the exact unit |
| Weight | Verify from the exact unit |
| Country of Origin | United States, as stated in the seller listing |
| Product Condition | Seller refurbished, according to the listing |
| Discontinued Status | Not confirmed |
Typical Applications
- Gas turbine control cabinets
- Steam turbine control systems
- Power-generation control equipment
- VME control and interface racks
- Industrial turbine monitoring systems
- Maintenance and replacement of compatible GE Mark VI power supplies
Frequently Asked Questions
Q1: What is the function of the IS2020RKPSG3A?
It supplies regulated DC power to compatible GE Mark VI VME rack components.
Q2: What is the rated output power?
The IS2020RKPSG3A model family is documented at approximately 400 W. Confirm the exact rating and configuration from the unit label and applicable technical manual.
Q3: What is the input voltage?
The applicable version is documented for a nominal 125 V DC input. Other versions within the broader IS2020RKPS family may have different input requirements, so verify the complete part number before connection.
Q4: What outputs does this module provide?
The documented model family provides several DC power rails and multiple +28 V DC power outputs. The precise output arrangement should be checked against the applicable GE documentation and rack wiring.
Q5: Is the IS2020RKPSG3A interchangeable with other IS2020RKPS models?
Not necessarily. Different model suffixes can indicate different input and output configurations. Confirm the complete part number, revision, and rack requirements before selecting a replacement.
Q6: What should I check before purchasing?
Verify the part number and revision, input-voltage rating, output configuration, connectors, mounting hardware, refurbishment or test records, and warranty terms.
Related GE Mark VI Components
The following components are associated with GE Mark VI control and power-distribution systems. They are related maintenance parts, not guaranteed direct replacements for the IS2020RKPSG3A.
- IS2020RKPSG1A – VME rack power supply variant
- IS2020RKPSG2A – VME rack power supply variant
- IS2020RKPSG1AD – RKPS family variant
- IS2020RKPSG1AG – RKPS family variant
- IS2020RKPSG1AI – RKPS family variant
- IS2020LVPSG1 – Low-voltage power supply board family
- IS200VCMIH2B – VME control and interface module
- IS200VPROH1B – Protection processor board
- IS200VCRCH1B – VME control rack component
- IS200VGENH1B – Generator interface board family
- IS200VRTDH1D – RTD input board family
- IS200TBAIH1C – Analog input terminal board
- IS200TBCIH1C – Contact input terminal board
- IS200TBDOH1C – Discrete output terminal board
- GE Mark VI VME Rack Components – Rack-level power, control, and interface hardware
Confirm exact model identifiers and system compatibility before ordering related parts.
Ordering Information
When requesting a quotation, specify GE IS2020RKPSG3A Rev FFN Mark VI VME Rack Power Supply Module and the required quantity.
Before purchase, verify the complete nameplate, input voltage, output configuration, revision marking, physical condition, test documentation, and warranty. Installation should follow the applicable GE Mark VI technical documentation and approved equipment isolation procedures.














_副本.jpg)