GE Multilin 489-P5-LO-A20-E | Generator Management Relay

Original price was: ¥99,999.00.Current price is: ¥1,588.00.

This image and price are not for reference. If you need to inquire, please contact me!

🌍Country of origin: USA France Germany Estonia Norway UK

⌚Delivery date: in stock

🛠After-sales service: brand new with one year warranty

⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen

🕰Warranty: 12 months/365 days

☎️ Please contact me: 15359029662 Ms. Amy Sun

📎Chinese official website: www.dcsplcabb.com

📩Email: geabbamy@gmail.com

💬Whatsapp: +86 15359029662 

If you have any products that you cannot find, you can consult anytime.

Detailed content

Product Description

The GE Multilin 489-P5-LO-A20-E is a Generator Management Relay from the Multilin 489 series, designed for protection, monitoring, and control of synchronous and induction generators. The P5 configuration uses 5 A phase CT secondaries, while the LO power-supply option supports 20–60 VDC or 20–48 VAC at 48–62 Hz. The A20 option provides 4–20 mA analog outputs, and the E enhancement provides the enhanced display and keypad. The relay provides generator electrical protection functions together with RTD monitoring, analog transducer inputs, digital inputs, output relays, and serial/Ethernet communication interfaces. GE documentation identifies the 489 as suitable for generator applications operating at 25, 50, or 60 Hz.

Product Datasheet

Specification Details
Brand GE Multilin
Model 489-P5-LO-A20-E
Series Multilin 489
Product Name Generator Management Relay
Product Type Generator Protection & Management Relay
Phase CT Input 5 A phase CT secondaries
Control Power 20–60 VDC / 20–48 VAC, 48–62 Hz
Analog Outputs 4 × 4–20 mA
Analog Inputs 4 configurable analog transducer inputs
RTD Inputs 12 field-programmable RTD inputs
Digital Inputs 9 opto-isolated / assignable inputs
Output Relays 6 electromechanical Form-C relays
Voltage Inputs Generator phase and neutral VT inputs
Communication 1 × RS232, 2 × RS485
Ethernet 10BaseT Ethernet on E/T enhanced configurations
Protocols Modbus RTU, DNP 3.0
Display Enhanced LCD display
Frequency 25 / 50 / 60 Hz applications
Operating Temperature Approximately -40 to +60 °C
Manual GEK-106494L
Product Status Legacy GE Multilin relay
Application Synchronous and induction generator protection

Functional Features

  • Generator protection and management functions in one relay
  • 5 A phase CT input configuration
  • 12 RTD inputs for generator temperature monitoring
  • Four 4–20 mA analog outputs
  • Four configurable analog transducer inputs
  • Nine opto-isolated digital inputs
  • Six Form-C output relays
  • Front RS232 communication interface
  • Two rear RS485 communication interfaces
  • Enhanced display and keypad for local configuration and monitoring
  • 10BaseT Ethernet capability associated with the enhanced communication configuration
  • Supports Modbus RTU and DNP 3.0 communication
  • Suitable for synchronous and induction generator applications
  • Designed for industrial power-generation protection and monitoring

FAQ

Q: What is the GE Multilin 489-P5-LO-A20-E?
A: It is a GE Multilin 489-series Generator Management Relay used for generator protection, monitoring, control, and measurement.

Q: What does P5 mean in the model number?
A: P5 identifies the 5 A phase CT secondary configuration.

Q: What does LO mean?
A: LO identifies the low-voltage control-power version, supporting 20–60 VDC or 20–48 VAC at 48–62 Hz.

Q: What does A20 mean?
A: A20 identifies the 4–20 mA analog-output configuration.

Q: What does the E suffix indicate?
A: E identifies the enhanced display configuration, including the larger display and improved keypad. GE’s ordering information distinguishes E from T, with T adding a 10BaseT Ethernet port.

Q: How many RTD inputs are available?
A: The relay provides 12 field-programmable RTD inputs.

Q: Which communication interfaces are available?
A: The configuration includes a front RS232 port and two rear RS485 ports. Compatible configurations support Modbus RTU and DNP 3.0.

Q: Can this relay be used with both synchronous and induction generators?
A: Yes. The 489 series is designed for both synchronous and induction generator applications.

Q: What should be checked before replacement?
A: Confirm the complete part number 489-P5-LO-A20-E, CT rating, control-power range, analog-output configuration, communication options, firmware, and existing protection settings.

Troubleshooting & Safety

Relay does not power up: Verify that the control supply is within the LO input range and that polarity, wiring, and protective devices are correct.

Incorrect current measurements: Confirm that the generator CT secondary rating is 5 A and check CT wiring, polarity, phase assignment, and relay settings.

RTD alarm or incorrect temperature: Check the RTD type, three-wire connections, sensor resistance, terminal wiring, and channel configuration.

Analog output problem: Verify that the application expects 4–20 mA outputs and check loop wiring, load resistance, and configured output assignment.

Communication problem: Check RS232/RS485 wiring, baud rate, parity, device address, protocol selection, and Ethernet configuration where applicable.

Protection operation: Do not change generator protection settings without confirming the required values against the generator protection study and site commissioning documentation.

Safety: Generator protection circuits can involve hazardous voltage and high-energy CT circuits. Isolate equipment according to site procedures and follow appropriate lockout/tagout practices. Never open-circuit an energized CT secondary.

Recommended GE Multilin Models

  1. 489-P1-LO-A20-E – 489 Generator Management Relay, 1 A CT configuration
  2. 489-P5-LO-A20-E – 489 Generator Management Relay, 5 A CT / 4–20 mA configuration
  3. 489-P5-LO-A1-E – 489 Generator Management Relay with 0–1 mA analog outputs
  4. 489-P5-HI-A20-E – 489 Generator Management Relay, high-voltage power supply
  5. 489-P5-LO-A20-T – 489 Generator Management Relay with enhanced Ethernet configuration
  6. 489-P5-HI-A20-T – 489 Generator Management Relay, high-voltage Ethernet configuration
  7. 489-P1-LO-A1-E – 489 Generator Management Relay, 1 A CT / 0–1 mA configuration
  8. 489-P1-HI-A20-E – 489 Generator Management Relay, 1 A CT / high-voltage supply
  9. 489-P5-LO-A1-T – 489 Generator Management Relay with Ethernet
  10. 489-P1-LO-A20-T – 489 Generator Management Relay, 1 A CT / Ethernet
  11. 469-P5-HI-A20 – Multilin Motor Management Relay
  12. 469-P5-HI-A20-E – Enhanced Multilin Motor Management Relay
  13. 369-HI-R-M-0-0-0 – Multilin Motor Management Relay
  14. 745-W2-P5-G5-HI – Multilin Transformer Protection Relay
  15. 750-P5-G5-S1-HI-A20-R-E – Multilin Feeder Protection Relay