Detailed content
The GE MULTILIN UR-9NH CPU Module is a communication and processing module designed for GE Multilin Universal Relay (UR) Series protection systems. It provides the main processing capability for UR relays while adding RS485 serial communication and 10/100Base-T Ethernet connectivity for integration with SCADA systems, PLCs, and industrial communication networks.
The UR-9NH CPU module is part of the GE Multilin replacement CPU module family. It supports Ethernet-based communication including Modbus TCP/IP and DNP communication protocols, while the RS485 interface provides serial communication capability for remote monitoring and control applications.
This CPU module is commonly installed in GE Multilin UR Series protection relays including feeder, transformer, motor, generator, and line protection systems. It is supplied as a replacement spare for maintaining existing GE protection equipment in utility, power generation, and industrial automation applications.
📋 Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | GE MULTILIN |
| Model | UR-9NH |
| Series | Universal Relay (UR) Series |
| Product Name | CPU Module / Processor Communication Module |
| Part Number | A9NC09002615 (Configuration Dependent) |
| Module Type | Protection Relay CPU Module |
| Product Status | Used / Surplus Stock |
| Application | Feeder Protection, Transformer Protection, Generator Protection, Industrial Power Automation |
| Communication Interface | RS485 + 10/100Base-T Ethernet |
| Communication Protocol | Modbus RTU, Modbus TCP/IP, DNP 3.0 (Configuration Dependent) |
| Processor Function | Relay Logic Processing, Data Management, Communication Control |
| Ethernet Port | 10/100Base-T |
| Serial Port | RS485 |
| Dimensions | Approx. 160 × 120 × 40 mm |
| Weight | Approx. 0.5 kg |
| Origin / Place of Origin | Canada / United States (Configuration Dependent) |
| Power Supply | Supplied by UR Relay Chassis |
| Installation Type | UR Relay Rack / Module Slot Mounted |
| Operating Temperature | Approx. -40°C to +60°C |
| Discontinued Status | Legacy Module / Spare Replacement Available |
❓ Common Questions & Answers
Q: What is the main function of GE MULTILIN UR-9NH CPU Module?
A: The UR-9NH provides the processing core and communication functions for GE Multilin Universal Relay systems, handling relay logic execution, data processing, and network communication.
Q: Which GE Multilin relays use the UR-9NH CPU module?
A: It is used across GE Multilin UR Series protection relays, including feeder, transformer, generator, and motor protection platforms depending on relay configuration.
Q: What communication ports are available on UR-9NH?
A: The module provides one 10/100Base-T Ethernet communication interface and one RS485 serial communication interface.
Q: Is UR-9NH a complete protection relay?
A: No. It is a replaceable CPU and communication module installed inside a GE Multilin UR Series relay chassis.
Q: What are common causes of UR-9NH failure?
A: Common issues include unstable relay power supply, communication network faults, damaged Ethernet/RS485 ports, firmware problems, and aging electronic components.
Q: What should be checked before replacement?
A: Verify the complete relay model, existing CPU module type, firmware version, serial number, communication settings, and hardware compatibility before installation.
Q: Can UR-9NH replace other UR CPU modules?
A: Replacement depends on the required communication interface, relay model, firmware compatibility, and system configuration. The original CPU type should be confirmed before replacement.
Q: Is GE MULTILIN UR-9NH still manufactured?
A: UR-9NH modules are mainly maintained as replacement components for installed GE Multilin UR Series systems and are commonly available through industrial spare-part channels.
⭐ Recommended GE MULTILIN Models
- GE MULTILIN UR-9NH – CPU Module RS485 / 10-100Base-T
- GE MULTILIN UR-9E – CPU Module RS485 / RS485
- GE MULTILIN UR-9G – CPU Module RS485 / Ethernet
- GE MULTILIN UR-9H – Redundant Ethernet CPU Module
- GE MULTILIN UR-9J – 100Base-FX Fiber CPU Module
- GE MULTILIN UR-9K – Redundant Fiber CPU Module
- GE MULTILIN UR-9L – Single Mode Fiber CPU Module
- GE MULTILIN UR-9M – Redundant Single Mode Fiber CPU Module
- GE MULTILIN UR-9P – Fiber Communication CPU Module
- GE MULTILIN UR-9R – Redundant Fiber CPU Module
- GE MULTILIN F60 Feeder Management Relay
- GE MULTILIN T60 Transformer Protection Relay
- GE MULTILIN G60 Generator Protection System
- GE MULTILIN L60 Line Differential Protection Relay
- GE MULTILIN 350 Feeder Protection System