Product code: N/A
HIMA | 982200480 | HIMatrix F2 DO 16 01 Safety Digital Output Module
¥99,999.00 Original price was: ¥99,999.00.¥1,588.00Current price is: ¥1,588.00.
This image and price are not for reference. If you need to inquire, please contact me!
🌍Country of origin: USA France Germany Estonia Norway UK
⌚Delivery date: in stock
🛠After-sales service: brand new with one year warranty
⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen
🕰Warranty: 12 months/365 days
☎️ Please contact me: 15359029662 Ms. Amy Sun
📎Chinese official website: www.dcsplcabb.com
📩Email: geabbamy@gmail.com
💬Whatsapp: +86 15359029662
If you have any products that you cannot find, you can consult anytime.
Detailed content
Product Introduction
The HIMA 982200480 HIMatrix F2 DO 16 01 SILworX is a safety-related remote I/O module designed for industrial automation and safety instrumented systems. It provides 16 digital output channels for controlling compatible field devices, such as relays, solenoid valves, and other actuators in safety-related applications.
Operating from a 24 VDC supply, the module communicates with compatible HIMax or HIMatrix controllers through HIMA’s safeethernet network. Its safety-related output architecture supports monitoring and fault detection, helping the control system respond appropriately when an output fault occurs.
Part number 982200480 identifies the SILworX-compatible version of the HIMatrix F2 DO 16 01. It is intended for applications where dependable output control and system diagnostics are important, including process automation, industrial machinery, and safety-related control systems.
Key Features
- Manufacturer: HIMA Paul Hildebrandt GmbH + Co. KG
- Model: HIMatrix F2 DO 16 01 SILworX
- Part Number: 982200480
- Product Type: Safety-Related Digital Output Remote I/O
- Output Channels: 16 digital outputs
- Operating Voltage: 24 VDC
- Output Current: Up to 2 A per channel below 40°C, subject to group and total current limits
- Communication: Two RJ45 Ethernet ports with integrated switch
- Network: HIMA safeethernet
- Configuration Software: SILworX for supported operating system versions
- Mounting: 35 mm DIN rail
- Safety Application: Certified for applicable safety-related applications; confirm the required certification and system configuration
Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | HIMA |
| Model | HIMatrix F2 DO 16 01 SILworX |
| Part Number | 982200480 |
| Series | HIMatrix |
| Product Name | Safety-Related Digital Output Remote I/O |
| Place of Manufacture / Origin | Germany; verify product nameplate |
| Product Status | Confirm with seller |
| Dimensions | Approx. 207 × 114 × 66 mm (W × H × D) |
| Weight | Approx. 0.9 kg |
| Country of Origin | Verify product nameplate |
| Power Requirements | 24 VDC, -15% to +20%, from a suitably isolated power supply |
| Digital Outputs | 16, arranged in two groups of 8 |
| Output Current | Max. 2 A per channel below 40°C; max. 1 A per channel at 40–60°C |
| Group Current | Max. 8 A per group |
| Total Permissible Output Current | Max. 16 A across both groups, subject to operating conditions |
| Communication Interface | 2 × RJ45, 10/100 Mbps Ethernet |
| Configuration Software | SILworX |
| Mounting | 35 mm DIN rail |
| Protection Rating | IP20 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Discontinued | Current lifecycle status not verified |
Installation and Compatibility Notes
- Verify that the installed controller and remote I/O configuration support the 982200480 SILworX variant.
- Supply the module with a suitably isolated 24 VDC power source that meets the manufacturer’s electrical requirements.
- The 16 outputs are divided into two separately supplied groups of eight channels. Observe the specified group-current and total-current limits.
- Connect both Ethernet ports according to the approved network topology and safeethernet configuration.
- Configure the module using the appropriate SILworX version for the installed system and firmware.
- Maintain the required ventilation clearances and ensure the DIN rail mounting is secure.
- Before commissioning, verify output wiring, diagnostics, fault responses, and the safety function through the approved proof-test procedure.
Because this is a safety-related output module, installation, configuration, and testing must follow HIMA documentation and the site’s functional-safety procedures.
Frequently Asked Questions
Q1: What is the HIMA 982200480 used for?
It provides 16 safety-related digital output channels for controlling compatible field devices in industrial automation and safety systems.
Q2: What does SILworX mean in the product name?
SILworX is HIMA’s engineering and configuration environment. The 982200480 version is intended for compatible SILworX-based HIMatrix configurations.
Q3: What is the operating voltage?
The specified operating supply is 24 VDC, with a permitted range of -15% to +20%, using a suitably isolated power supply.
Q4: What is the maximum output current?
The module supports up to 2 A per channel below 40°C and up to 1 A per channel at 40–60°C. Each group of eight outputs is limited to 8 A, with a maximum total of 16 A under the specified operating conditions.
Q5: Can it work with a standard PLC?
It is designed for compatible HIMA safety-related controller systems using safeethernet. It should not be assumed to operate as a standalone general-purpose PLC output module.
Q6: Is this module suitable for safety instrumented systems?
It is designed for safety-related applications. Actual suitability depends on the complete system architecture, approved configuration, certification requirements, and application-specific safety assessment.
Q7: What should I verify before purchasing?
Confirm the full part number, SILworX compatibility, hardware and firmware revisions, physical condition, terminal accessories, and the configuration of the installed HIMA system.
Recommended Related HIMA Models and Components
The following are related HIMA safety-system components and product families worth considering when maintaining or expanding a compatible installation. They are not direct substitutes unless confirmed by the system documentation.
- HIMatrix F2 DO 16 01 — Remote I/O module with 16 digital outputs.
- HIMatrix F2 DO 16 014 SILworX — Related temperature-range variant; verify the exact ordering code.
- HIMatrix F2 DI 16 01 — Digital input remote I/O family.
- HIMatrix F2 AI 8 01 — Analog input remote I/O family; verify the required variant.
- HIMatrix F2 SI 4 01 — Safety-related input module family; confirm the exact model.
- HIMatrix F60 — Modular safety controller platform.
- HIMax — HIMA high-availability safety controller platform.
- HIMatrix compact systems — Compact safety controller and remote I/O family.
- HIMA safeethernet — Safety-related Ethernet communication technology.
- HIMA SILworX — Engineering and configuration software for supported HIMA systems.
- HIMA ELOP II Factory — Engineering environment for compatible earlier HIMA configurations.
- HIMatrix F1 DI 16 01 — Digital input module family; verify system and firmware compatibility.
- HIMatrix F1 DO 16 01 — Digital output module family; verify its electrical and configuration requirements.
- HIMA HIMatrix power supply components — Power components suitable for the installed system.
- HIMA system connection accessories — Compatible connectors and wiring accessories for the specified remote I/O model.
Purchasing Reminder
Before ordering, confirm that the required part number is 982200480, the SILworX-compatible version of the HIMatrix F2 DO 16 01. Check the actual hardware label, firmware requirements, product condition, included connectors, and return terms. For safety-related applications, verify compatibility with the existing controller and approved system configuration before installation.