Product Introduction
The Purafil OnGuard CCT (Continuous Corrosion Transmitter) is an environmental monitoring instrument designed to measure atmospheric corrosion on copper and silver surfaces in real time. It helps facility operators assess corrosive gas contamination and identify environmental conditions that may damage sensitive electronic equipment.
The OnGuard CCT transmits corrosion measurement data to a compatible process control system through a 4–20 mA analog output. It is suitable for applications such as control rooms, electrical equipment rooms, data centers, and industrial facilities where corrosion monitoring helps protect electronic systems and reduce maintenance risks.
The supplied listing identifies the unit as A3 OnGuard CCT, with serial number 123. Confirm the exact model designation, sensor condition, output configuration, and included accessories before ordering.
Key Features
- Manufacturer: Purafil
- Model designation: A3 OnGuard CCT
- Product type: Continuous Corrosion Transmitter
- Measures corrosion forming on copper and silver surfaces
- Provides real-time atmospheric corrosion monitoring
- Transmits measurement data through a 4–20 mA analog output
- Supports environmental assessment for sensitive electronic equipment
- Intended for industrial facilities and critical equipment environments
- Sensor condition and calibration status should be verified before installation
Product Datasheet
| Specification | Details |
|---|---|
| Brand | Purafil |
| Model | A3 OnGuard CCT |
| Series | OnGuard |
| Product Name | Continuous Corrosion Transmitter |
| Product Type | Atmospheric Corrosion Monitoring Instrument |
| Measurement | Corrosion on copper and silver surfaces |
| Output Interface | 4–20 mA analog output |
| Update Interval | Approximately hourly for the documented OnGuard CCT family; verify the exact model |
| Accuracy | Approximately 0.5–1% of full span, as specified for the OnGuard CCT family |
| Sensor Service Life | Up to 4,000 angstroms of cumulative corrosion, depending on the sensor and operating conditions |
| Serial Number | 123 |
| Place of Manufacture / Origin | Not independently verified |
| Product Status | Confirm with seller |
| Dimensions | Not verified |
| Weight | Not verified |
| Country of Origin | Confirm from the product label |
| Power Requirements | Confirm from the exact model’s technical documentation |
| Discontinued | Current lifecycle status not verified |
Installation and Compatibility Notes
- Confirm the exact OnGuard CCT model and the meaning of the A3 designation from the equipment label or manufacturer documentation.
- Verify the 4–20 mA output wiring and input compatibility with the receiving PLC, DCS, or facility monitoring system.
- Confirm the required power supply and grounding arrangements before installation.
- Check sensor condition and cumulative corrosion exposure, as sensor service life depends on the amount of corrosion measured.
- Install the transmitter in a representative location where environmental monitoring data will be useful for the protected equipment.
- Compare readings with the applicable environmental classification criteria and the manufacturer’s guidance.
- Installation and commissioning should be performed by qualified instrumentation personnel.
Frequently Asked Questions
Q1: What is the Purafil OnGuard CCT used for?
It continuously monitors corrosion on copper and silver surfaces and transmits measurement data to a compatible process control system.
Q2: What output does the OnGuard CCT use?
The documented OnGuard CCT family uses a 4–20 mA analog output for integration with compatible control and monitoring systems.
Q3: What environments can it monitor?
Typical applications include control rooms, data centers, electrical rooms, and industrial facilities where airborne contaminants may cause corrosion of electronic equipment.
Q4: How often are readings updated?
Documentation for the OnGuard CCT family describes readings updated approximately once per hour. Verify this interval for the exact unit being purchased.
Q5: Does the unit require sensor replacement?
Yes, sensor service life is limited by cumulative corrosion exposure. Confirm the sensor condition and replacement requirements before putting a used unit into service.
Q6: Is this unit tested and calibrated?
The listing details do not establish its current test or calibration status. Confirm the seller’s test results, sensor condition, and any available calibration documentation.
Recommended Related Purafil OnGuard Models and Components
The following products and components are related to Purafil environmental and corrosion monitoring. They are not all direct replacements for the A3 OnGuard CCT.
- Purafil OnGuard CCT — Continuous Corrosion Transmitter
- Purafil OnGuard 2000 — Atmospheric Corrosion Monitor
- Purafil OnGuard 3000 — Atmospheric Corrosion Monitor
- Purafil OnGuard 4000 — Atmospheric Corrosion Monitor
- Purafil OnGuard Smart — Corrosion and environmental monitoring system
- Purafil OnGuard ERM — Environmental Reactivity Monitor
- Purafil OnGuard A-Prompt — Air quality monitoring accessory
- Purafil OnGuard Copper Sensor — Replacement copper corrosion sensor
- Purafil OnGuard Silver Sensor — Replacement silver corrosion sensor
- Purafil OnGuard Relative Humidity Sensor — Environmental sensing component
- Purafil OnGuard Temperature Sensor — Temperature monitoring component
- Purafil Corrosion Classification Coupon — Corrosion assessment accessory
- Purafil CCC+ — Corrosion classification and environmental monitoring accessory
- Purafil OnGuard 4–20 mA Interface Components — Analog signal integration accessories
- Purafil OnGuard Communication Accessories — Verify the exact compatible part numbers
Confirm model numbers, sensor compatibility, and output requirements before purchasing related equipment.
Purchasing Reminder
Before ordering, verify the A3 OnGuard CCT identification, serial number 123, physical condition, sensor service life, output configuration, and testing status. For used corrosion monitoring equipment, sensor condition and verified output performance are especially important for reliable integration with a facility control system.