Product code: N/A
Rolls-Royce | AIO1036 V2 | Marine Analog I/O Interface Card
¥66,666.00 Original price was: ¥66,666.00.¥1,450.00Current price is: ¥1,450.00.
Product images and prices are not for reference. Please contact me for a quote!
🌍Country of origin: USA France Germany Estonia Norway UK
⌚Delivery date: in stock
🛠After-sales service: brand new with one year warranty
⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen
🕰Warranty: 12 months/365 days
☎️ Please contact me: 15359029662 Ms. Amy Sun
📎Chinese official website: www.dcsplcabb.com
📩Email: geabbamy@gmail.com
💬Whatsapp: +86 15359029662
Detailed content
-
Product Description
The Rolls-Royce AIO1036 V2 is an analog input/output interface card associated with the Ulstein Propeller HELICON-X marine propulsion control system.
The card provides an interface between the vessel’s control electronics and external analog field signals. It is used for acquiring measurement signals from propulsion and machinery instrumentation and transmitting analog control signals to connected equipment.
The AIO1036 family uses configurable analog input and output circuits. Available hardware documentation describes jumper-selectable signal configurations, including voltage and current modes. This allows the card to be configured for different sensor and actuator interface requirements.
Typical applications include propeller pitch control, propulsion monitoring, actuator feedback, and other marine automation functions.
Product Parameters
- Brand: Rolls-Royce Marine / Ulstein Propeller
- Model: AIO1036 V2
- Related Hardware Designation: AIO1036A / AIO1036C V2
- PCB Marking Reference: RRAIO1036.v2
- Product Name: Analog Input/Output Interface Card
- Product Category: Marine Automation Control PCB
- System Association: HELICON-X marine propulsion control system
- Input Type: Configurable analog voltage/current inputs
- Output Type: Configurable analog voltage/current outputs
- Signal Configuration: Jumper-selectable
- Documented Signal Modes: +10 V and 0–20 mA, depending on channel configuration
- Channel Count: Confirm from the exact PCB revision and hardware documentation
- Installation: Control-system electronic unit / card assembly
- Communication: System internal interface; exact V2 interface details require verification
- Place of Manufacture: Norway association; supplied unit origin requires label verification
- Product Status: Confirm the condition of the supplied unit
- Dimensions: Not independently verified for AIO1036 V2
- Weight: Not independently verified
- Power Requirements: Confirm from the applicable V2 hardware documentation
- Country of Origin: Verify from the product label
- Discontinued Status: Confirm with Rolls-Royce Marine / Ulstein documentation
Main Features
- Analog signal acquisition for marine propulsion control
- Analog output interface for external control equipment
- Configurable input and output signal modes
- Jumper-based signal selection on documented hardware versions
- Interface between field instrumentation and central propulsion control electronics
- Designed for marine control cabinet installation
- Supports propulsion and machinery monitoring applications
- Used in legacy Rolls-Royce / Ulstein marine automation systems
Typical Applications
- Main propulsion remote control systems
- Controllable-pitch propeller systems
- Propeller pitch feedback and indication
- Hydraulic actuator control interfaces
- Marine machinery monitoring
- Vessel propulsion automation
- Thruster and steering control interfaces
- Shipboard analog sensor acquisition
Installation and Commissioning
- Check the PCB label and confirm whether the supplied card is AIO1036A, AIO1036C V2, or another revision.
- Verify the system designation and confirm that the card belongs to the vessel’s installed HELICON-X configuration.
- Compare the PCB layout, connectors, and component revisions with the original installed card.
- Disconnect the relevant control-system power before removing or installing the card.
- Record the existing jumper positions before making any configuration changes.
- Verify the required input and output signal types for each connected field circuit.
- Check the field wiring, connector condition, grounding, and shielding.
- Install the card in the specified position and secure all connections.
- Restore power according to the vessel’s approved commissioning procedure.
- Check analog input readings and output responses using approved test equipment.
- Verify propulsion feedback, control commands, alarms, and system diagnostics.
- Complete functional testing before returning the propulsion control system to normal operation.
Important: Do not copy jumper settings from another AIO1036 revision without checking the corresponding hardware documentation. Incorrect voltage/current selection may cause inaccurate readings or damage connected equipment.
Daily Maintenance and Care
- Inspect the PCB for corrosion, contamination, and physical damage.
- Check connectors and terminal interfaces for looseness.
- Inspect jumper positions and confirm they match the approved configuration.
- Monitor analog input values for abnormal fluctuations.
- Verify analog output responses during scheduled maintenance.
- Check associated sensor and actuator wiring.
- Inspect the control cabinet for moisture, vibration, and excessive temperature.
- Record any alarms, signal deviations, or card replacement history.
Troubleshooting and Common Questions
Q1: What is the function of the AIO1036 V2?
A: It provides analog input and output interfaces between field instrumentation and the Rolls-Royce / Ulstein marine propulsion control system.
Q2: Is the AIO1036 used in HELICON-X systems?
A: Yes. The AIO1036 family is associated with the HELICON-X marine propulsion control platform.
Q3: Does the card support both voltage and current signals?
A: The documented AIO1036 hardware uses jumper-selectable voltage and current modes. The exact available modes must be confirmed against the supplied revision.
Q4: What should be checked if an analog input reading is incorrect?
A: Check the field transmitter, wiring, connector contacts, signal reference, and jumper configuration. Compare the signal with a calibrated test source.
Q5: What should be checked if an analog output is abnormal?
A: Inspect the configured output mode, connected actuator circuit, wiring continuity, and control-system output command. Verify the signal with suitable test equipment.
Q6: Can AIO1036A and AIO1036C V2 be used interchangeably?
A: Interchangeability has not been established. Confirm PCB revision, connector arrangement, jumper configuration, and system compatibility before substitution.
Q7: What information should be provided when ordering?
A: Provide the full model designation, PCB revision, serial number, connector photographs, and any additional markings such as RRAIO1036.v2 or 10405.
Safety Precautions
- Only qualified marine automation personnel should install or service the card.
- Isolate control power before handling the PCB.
- Record all jumper settings before removal or adjustment.
- Confirm voltage/current selection before connecting field devices.
- Use appropriate ESD protection when handling electronic assemblies.
- Do not change propulsion control parameters without authorization.
- Perform functional checks under the vessel’s approved safety and commissioning procedures.
Recommended Related Rolls-Royce / Ulstein Models
The following are related marine propulsion and HELICON-X control-system components. They are not confirmed direct replacements for AIO1036 V2.
- DIO1037A – Digital I/O interface card
- PFI1038 – Pulse/frequency interface card
- PFI1038B – Pulse/frequency interface card, later version reference
- PIC1041 – Panel interface card
- BLS1034A – Backup lamp switch card
- LSI1042B – Marine control-system PCB card
- PIB1039A – Pitch indication and backup card
- PDM1040B – Power distribution / monitoring card reference
- PCC1030D – Control-system PCB reference
- IDAI035C – HELICON-X electronic unit hardware reference
- CCN 01 – CANMAN controller network component
- RRPWR2006 – Marine control-system power module
- RRDIO15 – Marine digital I/O alarm module
- WRC1021D – Marine valve controller card
- AIO1036A – Analog I/O interface card, related hardware designation