Product code: N/A
VIBRO-METER | 200-566-000-012 | VM600 IOCN Communication Interface Card
¥99,999.00 Original price was: ¥99,999.00.¥1,588.00Current price is: ¥1,588.00.
This image and price are not for reference. If you need to inquire, please contact me!
🌍Country of origin: USA France Germany Estonia Norway UK
⌚Delivery date: in stock
🛠After-sales service: brand new with one year warranty
⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen
🕰Warranty: 12 months/365 days
☎️ Please contact me: 15359029662 Ms. Amy Sun
📎Chinese official website: www.dcsplcabb.com
📩Email: geabbamy@gmail.com
💬Whatsapp: +86 15359029662
If you have any products that you cannot find, you can consult anytime.
Detailed content
Product Introduction
The Vibro-Meter 200-566-000-012 is an IOCN communication interface card for the Meggitt Vibro-Meter VM600 machinery protection and condition monitoring system. It works with a compatible CPUM processor card to provide external communication interfaces between the VM600 rack, plant control systems, and monitoring software.
The IOCN supports integration of machinery monitoring and protection data into industrial automation networks. Depending on the hardware configuration and firmware, its interfaces support Ethernet and serial communications for exchanging measurement information, alarms, event records, and system configuration data.
This module is used in applications involving turbines, compressors, pumps, and other critical rotating machinery. Confirm the IOCN revision, CPUM compatibility, and installed VM600 system configuration before ordering.
Key Features
- Manufacturer: Vibro-Meter / Meggitt
- Model: 200-566-000-012
- Product Family: VM600
- Module Designation: IOCN
- Product Type: Input/output and communication interface card
- Primary Function: Rack-level communication gateway
- Interfaces: Ethernet and serial communication, depending on configuration
- Serial Standards: RS-232 / RS-422 / RS-485 support is supplier-listed
- Communication Protocols: Modbus TCP and serial protocols; confirm firmware and configuration
- System Compatibility: Compatible VM600 rack with matching CPUM
- Application: Machinery protection and condition monitoring
Product Datasheet
| Parameter | Specification |
|---|---|
| Brand | Vibro-Meter |
| Model | 200-566-000-012 |
| Series | VM600 |
| Product Name | IOCN Communication Interface Card |
| Module Type | Input/output and communication card |
| Main Function | External communication for compatible VM600 rack |
| Compatible Processor | CPUM, subject to hardware and firmware compatibility |
| Ethernet Interface | Dual Ethernet interfaces, supplier-listed |
| Serial Interface | RS-232 / RS-422 / RS-485, configuration-dependent |
| Supported Protocols | Modbus TCP and supported serial protocols; verify exact configuration |
| Backplane | Compatible VM600 ABE04x rack |
| Power Supply | Via compatible VM600 rack backplane |
| Typical Power Consumption | Approximately 12 W, supplier-listed |
| Dimensions | 6U Eurocard format; exact width and depth depend on the card specification |
| Weight | Approximately 0.3–0.75 kg, supplier listings vary |
| Operating Temperature | Supplier-listed range approximately −20°C to +65°C; verify exact revision |
| Place of Manufacture | To be confirmed |
| Country of Origin | To be confirmed from the product label |
| Product Status | Specify actual inventory condition |
| Discontinued | Reported discontinued by some suppliers; confirm availability |
Typical Applications
- Steam and gas turbine machinery protection
- Compressor and pump condition monitoring
- Vibration monitoring system integration
- Communication between VM600 racks and DCS/PLC systems
- Machinery event and alarm reporting
- Maintenance of legacy VM600 installations
Installation and Troubleshooting
Before installation
- Verify the complete model number and IOCN hardware revision.
- Confirm the compatible CPUM card and ABE04x rack configuration.
- Check firmware compatibility and communication settings.
- Record existing Ethernet and serial connections before removing the original card.
If communication is unavailable
- Inspect Ethernet and serial cables and connectors.
- Verify network settings, device addressing, and protocol configuration.
- Check the IOCN and CPUM status indicators.
- Review system diagnostics and event logs.
If the card is not recognized
- Confirm that the module is installed in the correct rack position.
- Check the CPUM/IOCN combination against the equipment documentation.
- Inspect the card edge connector and rack backplane for damage.
Safety Precautions
- Follow approved maintenance procedures before removing rack modules.
- Confirm whether the specific rack configuration permits hot swapping; do not assume it is safe.
- Use electrostatic-discharge protection when handling the circuit card.
- Avoid interrupting active machinery protection communication without an approved maintenance plan.
- Verify communication and protection functions after replacement.
Frequently Asked Questions
Q1: What is the Vibro-Meter 200-566-000-012?
It is an IOCN communication interface card used in compatible VM600 machinery protection and condition monitoring systems.
Q2: What does IOCN mean?
IOCN refers to the VM600 input/output card used with a compatible CPUM to provide external interfaces and rack-level communications.
Q3: Can the IOCN work independently?
It is designed to work with a compatible CPUM and VM600 rack configuration. Verify the required card pairing before installation.
Q4: Which communication protocols does it support?
Supplier listings identify Ethernet-based Modbus TCP and serial communication support. Exact protocol availability depends on the card configuration, firmware, and system setup.
Q5: Is the model discontinued?
Some suppliers report that this version is discontinued. Check current availability and verify the condition of any surplus or refurbished unit.
Q6: Can it replace 200-566-000-112 or 200-566-101-012?
Do not assume direct interchangeability. Confirm hardware revision, firmware compatibility, connector configuration, and CPUM requirements against the VM600 documentation.
Recommended Related Vibro-Meter Models
The following are related VM600 modules and system components for cross-reference. They are not guaranteed direct replacements for 200-566-000-012.
- 200-566-101-012 – IOCN communication card variant
- 200-566-000-112 – IOCN communication card variant
- 200-566-000-113 – IOCN card variant
- 200-566-000-114 – IOCN card variant
- 200-566-101-013 – IOCN card variant
- 200-595-SSS-1Hh – CPU M processor card configuration
- 200-595-SSS-3Hh – CPU M configuration with additional Ethernet module
- 200-595-SSS-4Hh – CPU M configuration with additional serial communications module
- 200-560-000-016 – IOC4T module
- 204-040-100-011 – VM600 system rack
- 204-450-000-001 – IQS450 signal conditioner
- 200-570-101-013 – RLC16 relay card
- 200-530-100-013 – MPC4 machinery protection card family
- 200-530-075-013 – AMC8 machinery monitoring card family
- 224-124-000-021 – S3960 monitoring system component
Always verify the exact ordering number, module function, CPUM pairing, and firmware compatibility before selecting a replacement.













_副本.jpg)