YOKOGAWA | AIP830-111 | Single-Loop Operation Keyboard

Original price was: ¥66,666.00.Current price is: ¥2,355.00.

The price and pictures are not real!

🌍Country of origin: USA France Germany Estonia Norway UK

⌚Delivery date: in stock

🛠After-sales service: brand new with one year warranty

⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen

🕰Warranty: 12 months/365 days

☎️ Please contact me: 15359029662 Ms. Amy Sun

📎Chinese official website: www.dcsplcabb.com

📩Email: geabbamy@gmail.com

💬Whatsapp: +86 15359029662

Detailed content

  • Product Description

    The Yokogawa AIP830-111 is an industrial operation keyboard designed for single-loop operation at Yokogawa CENTUM VP and CENTUM CS 3000 Desktop-type Human Interface Stations (HIS).

    Unlike a standard computer keyboard, the AIP830-111 provides dedicated operation keys for process control, mode selection, and operator confirmation. Its specialized key layout allows operators to perform single-loop operations and access control functions directly from the keyboard.

    The AIP830-111 configuration includes a mode selection switch and Operation Confirmation Key Type B. It is suitable for control-room workstation maintenance, replacement, and spare-parts inventory.

    Product Parameters

    • Brand: Yokogawa
    • Model: AIP830-111
    • Product Name: Single-Loop Operation Keyboard
    • Product Type: Industrial DCS Operator Keyboard
    • Product Series: CENTUM VP Human Interface Station
    • Compatible Systems: CENTUM VP / CENTUM CS 3000
    • Operation Mode: Single-loop operation
    • Mode Selection Switch: Included
    • Operation Confirmation Key: Type B
    • Keyboard Interface: USB Type-A
    • USB Function: Keyboard operation and audio function
    • Power Supply: 5 VDC ±5%, supplied through USB
    • Maximum Current Consumption: 1 A
    • Weight: Approximately 2.0 kg without VESA bracket; 2.5 kg with bracket
    • Dimensions: Verify against the applicable installation drawing
    • Mounting: Desktop installation; optional VESA bracket
    • Option Codes: /VESA, /EIM, /JIM
    • Country of Origin: Verify from product nameplate
    • Product Status: Confirm actual inventory condition
    • Discontinued Status: Verify with Yokogawa

    Technical Specifications and Features

    • Dedicated Single-Loop Operation: Provides direct keyboard access to process loop operation and monitoring functions.
    • Mode Selection Switch: The -1 suffix identifies the version equipped with a mode selection switch.
    • Operation Confirmation Key Type B: The second suffix digit identifies the Type B confirmation key configuration.
    • Specialized Operation Keys: Provides dedicated keys for operator interaction with the CENTUM HIS environment.
    • Dual USB Connectivity: Uses USB Type-A connections for keyboard operation and the independent audio function.
    • Audio Feedback: Supports operator audio feedback through the USB speaker function.
    • VESA Mounting Option: The /VESA option provides a mounting bracket for compatible workstation installations.
    • System Integration: Designed for use with compatible Yokogawa Desktop-type HIS configurations.

    Industrial Applications

    • Power plant control rooms
    • Petrochemical process control
    • Oil and gas production facilities
    • Chemical manufacturing plants
    • CENTUM VP operator stations
    • CENTUM CS 3000 DCS workstations
    • Industrial process monitoring
    • Single-loop control and operator intervention

    Installation and Commissioning

    1. Confirm the full model number AIP830-111 and inspect the suffix identification.
    2. Verify that the target workstation supports the AIP830 operation keyboard.
    3. Shut down or isolate the workstation as required by the applicable maintenance procedure.
    4. Position the keyboard on the operator desk or install the optional VESA mounting bracket.
    5. Connect the keyboard USB cable to the designated workstation USB port.
    6. Connect the separate USB audio function where required by the workstation configuration.
    7. Restore workstation power and allow the operating system and HIS environment to initialize.
    8. Check alphanumeric keys, dedicated operation keys, mode selection, and confirmation-key functions.
    9. Verify audio feedback and confirm that the keyboard is recognized by the operator station.
    10. Complete an operational check using the approved DCS maintenance procedure.

    Daily Maintenance and Care

    • Keep the keyboard surface clean and free from dust and liquid contamination.
    • Check USB connectors and cables for wear or damage.
    • Inspect the mode selection switch for normal mechanical operation.
    • Test frequently used operation and confirmation keys.
    • Verify that the workstation recognizes the keyboard correctly.
    • Check the USB audio function if operator sound feedback is unavailable.
    • Store spare keyboards in clean, dry conditions.

    Troubleshooting and Common Questions

    Q1: What is the main function of the AIP830-111?

    A: It is a dedicated single-loop operation keyboard for compatible Yokogawa CENTUM VP and CENTUM CS 3000 operator stations.

    Q2: What does the -111 suffix mean?

    A: The first suffix digit indicates a mode selection switch, the second identifies Operation Confirmation Key Type B, and the final digit is the fixed code 1.

    Q3: Does the AIP830-111 require an external power adapter?

    A: It receives 5 VDC power through its USB connection. Confirm the workstation’s USB power capability.

    Q4: Can it be used as a standard PC keyboard?

    A: It is designed primarily for Yokogawa HIS operation. Its dedicated control keys require a compatible system environment.

    Q5: What is the difference between AIP830 and AIP831?

    A: AIP830 is designed for single-loop operation, while AIP831 is designed for simultaneous operation of up to eight loops. They serve different operator workflows.

    Q6: Is a VESA mounting bracket included?

    A: Only when the applicable /VESA option is specified. Confirm the supplied accessories before ordering.

    Q7: What should be checked if the keyboard is not recognized?

    A: Check USB connections, workstation compatibility, USB port status, cable condition, and the HIS configuration.

    Safety Precautions

    • Use the keyboard only with compatible Yokogawa operator stations.
    • Do not connect or disconnect cables during maintenance unless permitted by the workstation procedure.
    • Protect USB connectors from moisture and physical damage.
    • Avoid spilling liquids onto the keyboard.
    • Use the correct mounting hardware for VESA installation.
    • Do not operate dedicated control keys until the correct workstation and operating mode are confirmed.

    Recommended Related Yokogawa Models

    1. AIP830-001 – Single-Loop Operation Keyboard, without Mode Selection Switch
    2. AIP830-011 – Single-Loop Operation Keyboard, Confirmation Key Type A
    3. AIP830-101 – Single-Loop Operation Keyboard, without Mode Selection Switch
    4. AIP830-111/VESA – Single-Loop Operation Keyboard with VESA Bracket
    5. AIP830-111/EIM – Single-Loop Operation Keyboard with English Instruction Manual
    6. AIP831 – Eight-Loop Simultaneous Operation Keyboard
    7. VI702 – Vnet/IP Interface Card
    8. AIP125-S2 – Yokogawa Control Interface Module
    9. AIP121-S00 – Yokogawa Interface Board
    10. ALR121-S00 – Serial Communication Module
    11. ALP121-S00 – PROFIBUS-DP Communication Module
    12. AAI141 – Analog Input Module
    13. AAI543 – Analog Output Module
    14. AAT145 – Thermocouple/mV Input Module
    15. PW481 – Power Supply Module