You are here:
Product code: N/A

YOKOGAWA | AKB331-M25 | 25-Meter Digital I/O Signal Cable

Original price was: ¥99,999.00.Current price is: ¥1,588.00.

This image and price are not for reference. If you need to inquire, please contact me!

🌍Country of origin: USA France Germany Estonia Norway UK

⌚Delivery date: in stock

🛠After-sales service: brand new with one year warranty

⚙️ Product Category: Module/Controller/Server/Motor/Touch Screen

🕰Warranty: 12 months/365 days

☎️ Please contact me: 15359029662 Ms. Amy Sun

📎Chinese official website: www.dcsplcabb.com

📩Email: geabbamy@gmail.com

💬Whatsapp: +86 15359029662 

If you have any products that you cannot find, you can consult anytime.

Detailed content

  • Product Description

    The Yokogawa AKB331-M25 is a dedicated signal cable designed for industrial control-system I/O connections. It belongs to the AKB331 cable series used in Yokogawa CENTUM VP and related control-system installations.

    The AKB331 series is documented for connecting compatible 32-point digital I/O modules to relay boards. Typical applications include connections between ADV151 digital input modules or ADV551 digital output modules and compatible relay boards through the specified terminal arrangement.

    The M25 suffix identifies the 25-meter cable length. The cable provides a preconfigured connection between compatible system components, reducing the need for individual field wiring between the I/O module and relay board.

    This is a dedicated I/O signal cable, not an Ethernet, V-Net, or general-purpose fieldbus cable. Before ordering, verify the connector configuration, pin arrangement, and equipment at both ends.

    Product Parameters

    • Brand: Yokogawa
    • Model: AKB331-M25
    • Product Name: 25-Meter Digital I/O Signal Cable
    • Product Series: AKB331 Signal Cable Series
    • Cable Type: Dedicated industrial I/O signal cable
    • Cable Length: 25 meters
    • Connector Configuration: 50-pin to 50-pin reported for the AKB331-M25 cable variant; verify physical connectors
    • Typical Application: Digital I/O module-to-relay-board connection
    • Compatible System: Yokogawa CENTUM VP and specified compatible I/O configurations
    • Associated Digital Input Module: ADV151
    • Associated Digital Output Module: ADV551
    • Associated Relay Boards: ARM15A, ARM55D, ARM55W, ARM55T, ARM55C, and compatible ARS series
    • Cable Construction: Dedicated signal cable; exact conductor and shielding specifications to be verified
    • Operating Temperature: Confirm from the applicable cable specification
    • Minimum Bend Radius: Follow the applicable Yokogawa cable specification
    • Dimensions: Not confirmed
    • Weight: Not confirmed
    • Country of Origin: Not confirmed
    • Product Status: Verify current availability
    • Discontinued: Not confirmed

    Main Features

    • 25-Meter Cable Length: Provides an extended connection between compatible control-system components.
    • Dedicated I/O Connection: Designed for specific Yokogawa I/O and relay-board arrangements.
    • Preconfigured Connectors: Helps reduce individual wiring work and connection errors.
    • CENTUM VP Integration: Used in documented Yokogawa digital I/O connection configurations.
    • Industrial Installation: Suitable for control cabinets and approved system cable routing.
    • Maintenance Replacement: Useful for replacing damaged, missing, or incorrectly sized original cables.

    Installation and Commissioning

    1. Confirm the cable label reads AKB331-M25 and verify the 25-meter length.
    2. Check the connector type and pin arrangement against the original cable and equipment drawings.
    3. Confirm that the connected I/O module and relay board are approved for the AKB331 cable series.
    4. Isolate the relevant equipment according to the plant’s electrical safety procedures.
    5. Inspect both connectors for bent pins, contamination, corrosion, or damaged locking mechanisms.
    6. Route the cable between the designated equipment locations without excessive tension.
    7. Maintain the minimum bending radius specified by Yokogawa.
    8. Keep the cable away from high-voltage conductors and major sources of electromagnetic interference where required by the installation design.
    9. Secure the cable to prevent vibration, pulling, or accidental disconnection.
    10. Restore the equipment and verify I/O status and signal operation through the control-system diagnostics.

    Do not connect AKB331-M25 to an arbitrary 50-pin interface. A matching connector shape does not guarantee matching pin assignments or electrical compatibility.

    Daily Maintenance and Care

    • Inspect the cable jacket for cuts, abrasion, crushing, or chemical damage.
    • Check connector shells and locking mechanisms for mechanical wear.
    • Look for loose connections or intermittent I/O faults.
    • Keep connectors clean and protected from moisture and dust.
    • Avoid sharp bends and repeated movement near connector strain-relief points.
    • Check cable routing after cabinet maintenance or equipment relocation.
    • Record cable identification and installation location for future maintenance.
    • Replace cables with damaged insulation or unreliable connectors.

    Troubleshooting and Common Questions

    Q1: What is the function of AKB331-M25?

    It is a dedicated signal cable used to connect compatible Yokogawa digital I/O modules and relay boards in specified control-system configurations.

    Q2: What does M25 mean?

    The M25 suffix identifies a nominal cable length of 25 meters.

    Q3: Which Yokogawa modules use the AKB331 cable series?

    Yokogawa documentation identifies AKB331 for 32-point connections involving ADV151 digital input modules and ADV551 digital output modules with compatible relay boards.

    Q4: Can AKB331-M25 be used with ADV161 or ADV561?

    Do not assume compatibility. Yokogawa documentation specifies AKB337 for the corresponding 64-point relay-board connections. Confirm the complete connection arrangement before ordering.

    Q5: Is AKB331-M25 an Ethernet or V-Net cable?

    No. It is a dedicated I/O signal cable. It should not be treated as a general-purpose Ethernet or V-Net cable.

    Q6: Can I replace it with a standard 50-pin cable?

    Not without confirming the pin assignment, electrical characteristics, connector type, and equipment compatibility. A generic cable may have a similar connector but an incompatible wiring arrangement.

    Q7: What should be checked before purchase?

    Confirm the original cable model, required length, connector configuration, mating equipment, and the I/O module and relay-board models.

    Recommended Related Yokogawa Models

    The following products are related to the AKB331 I/O connection arrangement. They are associated system components or alternative cable lengths, not direct cable substitutes in every installation.

    1. AKB331-M001 – 1-Meter Signal Cable
    2. AKB331-M002 – 2-Meter Signal Cable
    3. AKB331-M003 – 3-Meter Signal Cable
    4. AKB331-M005 – 5-Meter Signal Cable
    5. AKB331-M007 – 7-Meter Signal Cable
    6. AKB331-M010 – 10-Meter Signal Cable
    7. AKB331-M015 – 15-Meter Signal Cable
    8. AKB331-M020 – 20-Meter Signal Cable
    9. AKB331-M030 – 30-Meter Signal Cable
    10. AKB331-M050 – 50-Meter Signal Cable
    11. AKB337 – Dedicated Signal Cable for 64-Point I/O Connections
    12. ADV151 – 32-Point Digital Input Module
    13. ADV551 – 32-Point Digital Output Module
    14. ARM15A – Mechanical Relay Board
    15. ARM55D – Mechanical Relay Board

    Safety Precautions

    • Verify the complete cable model and connector pin assignment before installation.
    • Do not connect the cable to equipment with an unverified interface.
    • Isolate the relevant circuits before connecting or disconnecting the cable.
    • Avoid pulling the cable by its connectors.
    • Follow Yokogawa cable-routing and minimum-bend-radius requirements.
    • Confirm I/O operation after installation before returning the control system to service.