SAACKE | K7-8385-602164 (SE@VIS FLUS 06 UV) | Electronic UV Flame Detector

Saacke K7-8385-602164 (SE@VIS FLUS 06-UV) is a precision-engineered ultraviolet flame detector and monitoring module designed specifically for industrial and marine combustion systems. Integrated within Saacke burner management and safety architectures, it continuously evaluates UV radiation from the burner flame to ensure rapid failure detection, immediate safety interlocks, and reliable protection against unburnt fuel accumulation.

SEAVIS SAACKE FLUS 06 UV FLAME DETECTOR K7-8385-602164 Image 1 of 4

📊 Technical Specifications

  • Brand: SAACKE (SE@VIS Series)

  • Model / Type: FLUS 06-UV (Ultraviolet Flame Detector)

  • Part / Item Number (MPN): K7-8385-602164 (Maker Ref: SAA602164 / Part No: 605884)

  • Place of Manufacture: Germany

  • Condition Status: Factory New / Industrial Surplus / Refurbished

  • Operating Voltage: 230 VAC, 50/60 Hz

  • Internal Fuse / Rating: Term. 11/12, Internal 500 mA

  • Flame Failure Response Time (FFDT): 1 second

  • Enclosure Protection Rating: IP20 (Panel or internal cabinet mounting)

  • Certification: CE-0085BL0172

  • Weight: Approx. 0.40 kg (400 g)

⚙️ Operational Guidelines & Usage Methods

  • Mount the detector module securely inside a protective burner control cabinet or switchboard rack, ensuring compliance with its IP20 rating away from direct exposure to moisture and heavy condensation.

  • Connect power input lines (230 VAC), terminal loops (such as terminals 11/12), and safety output wiring tightly in strict accordance with the official Saacke burner wiring schematic.

  • Verify optical alignment, clean sighting tubes, and check that background radiation sources do not trigger false flame-on signals prior to burner commissioning.

🔌 Power-On / Power-Off Sequence

  • Power-On Sequence: Confirm all wiring terminations, grounding paths, and internal fuses (500 mA) are securely in place. Apply the 230 VAC main control power supply to the unit. Observe status indicators to confirm that the sensor initializes and registers a clean “flame-off” state before initiating the burner ignition sequence.

  • Power-Off Sequence: Command the burner management system to a safe closed-purge or shut-down mode, ensuring all fuel shut-off valves are locked. Disconnect the 230 VAC electrical supply from the unit terminals prior to maintenance, inspection, or card extraction.

📖 Product Instructions

  • Periodically monitor the flame signal strength and response behavior using the system’s diagnostic interface during regular routine boiler checkups.

  • Inspect terminal blocks, wiring connections, and optical hardware during scheduled plant maintenance turns to ensure uninterrupted safety loop performance.

❓ Frequently Asked Questions (Q&A)

  • Q: What is the primary function of the Saacke FLUS 06-UV detector?

    • A: It provides real-time ultraviolet flame supervision, immediately tripping safety relays within 1 second if a flame failure occurs.

  • Q: What power supply does part number K7-8385-602164 require?

    • A: It operates on a standard 230 VAC, 50/60 Hz control voltage supply.

  • Q: What is the designated flame failure response time (FFDT)?

    • A: The flame failure detection time is rated at 1 second.

🔍 Recommended Related Series & Models

  • Saacke SE@VIS FSC-01 Burner Controller Module

  • Saacke FLS09 UV-5 Flame Sensor Module

  • Saacke SKV Rotary Cup Atomizer Assembly

  • Siemens QRB / QRA Flame Detector Series

  • Honeywell C7027A Minipeeper UV Flame Detector

  • Dungs DMV Dual Modular Gas Valve Assembly

  • Brahma Burner Control Box Series

  • ABB REM543 Machine Terminal Unit

  • Danfoss VLT Marine Frequency Converter Series

  • Woodward 2301D Digital Speed Governor

Share this story: